TROUBLE SHOOTING
Problem
What to check
Unit does
not start
•
Make sure the dehumidifier’s plug is pushed
completely into the socket outlet.
•
Check the house fuse/circuit breaker box.
•
Dehumidifier has reached its preset level or
drawer is full.
•
Drawer is not in the proper position.
Dehumidifier does not dry
the air as it should
•
Did not allow enough time to remove the
moisture.
•
Make sure there are no curtains, blinds or
furniture blocking the front or back of the
dehumidifier.
•
The humidity selector may not be set low
enough.
•
Check that all doors, windows and other
openings are securely closed.
•
Room temperature is too low, below 5 C(41 F).
• There is a kerosene heater or something giving
off water vapour in the room.
The unit makes a loud
sound when operating
•
The air filter is clogged.
• The unit is tilted instead of upright as it should
be.
•
The floor surface is not level.
Frost
appears on the coils
•
This is normal. The unit has Auto defrost
feature.
Water on the floor
•
Hose to connector or hose connection may be
loose.
•
Intend to use the drawer to collect water, but
the back drain plug is removed.
ES, AS, P1
or P2 appear on
the display
•
These are Error/Protection codes. Refer to
page 12 of the instruction manual.