NOTE – To comply with regulations, installation must be carried out
by qualified electrician and in accordance with the current IEE Wiring
Regulations (BS7671) and Building Regulations. A copy of the instructions
must be left for the user/maintenance engineer for future reference.
ENSURE ELECTRICAL SUPPLY IS DISCONNECTED/
ISOLATED BEFORE COMMENCING INSTALLATION
INSTRUCTIONS FOR NEW INSTALLATIONS
1. This luminaire requires a cut-out of 63 - 70mm, it is
recommended that the luminaire is installed in a 67mm cut-out.
The cut-outs need to be spaced to provide adequate clearance
from beams, pipes and electrical cables.
2. Twist bezel anti-clockwise to remove the bezel and LED module
for installation.
3. Insert ceiling bracket by lifting the springs to vertical and insert
into ceiling cut-out. Ensure the bracket assembly is positioned
centrally in the ceiling cut-out.
4. Pull electrical cables through the bracket. Recommended 20mm
of insulation and 5mm conductor length.
5. Wire mains and lamp to terminal block, ensuring correct polarity
of live/neutral. Downlight = Blue - Neutral, Brown - Live.
6. Align points on the bezel to ceiling bracket springs, insert and
rotate clockwise until tight.
7. Re-instate power and test.
PART CODE: LFR5WH255D40 / LFR5PC255D40 / LFR5BS255D40 / LFR5PC250D27 / LFR5WH250D27 / LFR5BS250D27
LFR7WH475D40 / LFR7PC475D40 / LFR7BS475D40 / LFR7PC450D27 / LFR7WH450D27 / LFR7BS450D27
Tech Help Line
UK -
0845 194 7584
Non UK -
+44 (0)1952 238 100
Visit our website at
Luceco is a registered trade mark of Nexus Industries Ltd.
Supplied by
BG Electrical Ltd
Stafford Park 1 TF3 3BD ENGLAND
www.luceco.co
LED Fire Rated
Downlight
Installation & Operating Instructions
V2KS-01/2014
Suitable for use with mains voltage of 180-240V AC.
This luminaire is compatible with most leading edge dimmers such as BG Electrical Triac Dimmers; please
check with dimmer manufacturer for compatibility with LED lighting, including min/max wattage loads.
Luminaire is only suitable for covering with blanket/roll type loft insulation material only.
IP65 rated luminaires are protected against dust and jets of water; it is suitable for installation in bathroom
zones 1 and 2 as defined by the IEE Wiring Regulations. IP65 only when installed as per instructions.
This luminaire is only suitable for indoor use.
This luminaire must be disconnected before insulation resistance testing of the lighting circuit.
Check for electrical cables and pipes before installation.
CRI
80
>
IP65
RATED
7
GUARANTEE
year
extended
90min
FIRE RATED
60min
FIRE RATED
30min
FIRE RATED
50,000
HOURS
1
SCALE 1.000
3
SCALE 3.000
L L
N
N
20mm 5mm
5
6
SCALE 1.000
4
SCALE 1.000
Cable
SCALE 1.000
Align
points on
the bezel
to ceiling
spring.
MainsDownlight
2
67mm
Blue
Brown
Question and Answer IconNeed help?

Do you have a question about the luceco LED Fire Rated Downlight and is the answer not in the manual?

luceco LED Fire Rated Downlight Specifications

General IconGeneral
Brandluceco
ModelLED Fire Rated Downlight
CategoryLighting Equipment
LanguageEnglish

Summary

LED Fire Rated Downlight

Important Safety & Compliance Notes

Compliance with regulations, qualified electrician requirement, and electrical supply isolation before installation.

Product Features & Suitability

Details compatibility with dimmers, loft insulation, IP rating, indoor use, and testing precautions.

New Installation Procedure

Step-by-step guide for new installations, covering cut-out size, bezel removal, wiring, and final fitting.

Replacing Existing Downlight

Replacement Installation Steps

Procedure for replacing an existing downlight, including power disconnection, wiring, and bracket insertion.

Environmental Protection (WEEE)

Guidance on the correct disposal of electrical products, emphasizing the WEEE symbol.

Product Guarantee Details

Information on the 3-year guarantee, extendable to 7 years, including terms and conditions.