363-205-401 Power Up: DLP-517
Issue 7, March 1997 Page 3 of 4
24. Have both
3C( ) RINGING GENERATOR
s been tested?
If
YES,
then proceed to Step
27.
If
NO,
then continue with Step
25.
25. Unseat
RING GEN1
.
26. Insert second
3C( ) RINGING GENERATOR
into
RING GEN2
slot in power
shelf and repeat from Step
3.
27. Reseat
RING GEN2
and press and hold
RG1 SHUTDOWN
button on
RSU
.
28. Is
FAIL
indicator on
RING GEN1
lighted and
FAIL
indicator on
RING GEN2
off?
If
YES,
then proceed to Step
31.
If
NO,
then continue with Step
29.
29. Release
RG1 SHUTDOWN
button and replace
RING GEN1
.
30. Unseat
RING GEN2
and repeat from Step
3.
31. Release
RG1 SHUTDOWN
button.
32. Press and hold
RG2 SHUTDOWN
button on
RSU
.
33. Is
FAIL
indicator on
RING GEN1
off and
FAIL
indicator on
RING GEN2
lighted?
If
YES,
then proceed to Step
36.
If
NO,
then continue with Step
34.
34. Release
RG2 SHUTDOWN
button and replace
RING GEN2
.
35. Unseat
RING GEN1
and repeat from Step
3.
36. Release
RG2 SHUTDOWN
button.
STOP. YOU HAVE COMPLETED THIS PROCEDURE.