RT Turn Up: DLP-501 363-205-401
Page 2 of 2 Issue 7, March 1997
4. Does any fuse(s) in
LFU
blow?
If
YES,
then continue with Step
5.
If
NO,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
5. Check wiring on dual bank assembly using SD-7C117-01 or SD-7C117-02 and
SD-7C118-01.
6. Is wiring correct?
If
YES,
then get another
LFU
and proceed to Step
2.
If
NO,
then continue with Step
7.
7. Repair wiring and use
WP0247 L201
insertion/extraction tool for
AUA115
LFU
; or
WECO 553A
extractor tool (Techni-Tool No. 594TE170) or
WECO
319B
(KS-6305) extractor tool (Techni-Tool No. 490PL020) for
39F LFU
, to
replace blown fuse(s).