363-205-401 RT Turn Up:
Issue 7, March 1997 Page 1 of 2
DLP-521
Verify Correct Complement of Circuit Packs for
FP303
1. Refer to Table A to determine the required number and complement of circuit
packs for feature package 303 (FP303).
2. Are all required packs available?
If
YES
, then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If
NO
, then obtain missing packs.
TABLE A
FP303 COMMON UNIT COMPATIBILITY
Unit
Code
Function
Code
Requirements
BCU MC97796A1 One BCU for each system (blue and white).
ADU AUB27B One ADU for each system (blue and white).
TRU AUA112B One TRU for each dual digroup shelf (two for each system);
one 993A TRU cable to connect TRUs.
LIU AUA61C, D, E
or F
AUA62C, D, E
or F
AUA64C, D, E
or F
One LIU for each equipped DS1; choose among unit codes.
LSU AUA74 One LSU for each system with DS1 protection switching.
CTU AUB22
AUB25
One CTU for each dual channel bank; choose between unit codes.
PCU AUA11( ) One PCU for each shelf of the dual channel bank.
CFU AUA114
39E
One CFU for each system; choose between unit codes.
LFU AUA115
39F
One LFU for each dual channel bank if equipped with AUA62C
or D LIUs; choose between unit codes.
FCU AUA24 One FCU is required for each system if a 2( ) fan unit is installed.