Conversions: DLP-515 363-205-401
Page 2 of 2 Issue 7, March 1997
7. Are all indicators listed in Table A lighted during LED test?
If
YES,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If
NO,
then continue with Step
8.
8. Are any of the indicators lighted during LED test?
If
YES,
then proceed to Step
4.
If
NO,
then continue with Step
9.
9. Replace
BCU
with
BCU
removed previously.
10.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Replace
ADU
. Verify that option switch settings on replacement
ADU
agree
with option switch settings on
ADU
being replaced.
11. Press and hold
LED TEST
pushbutton on
ADU
.
12. Are all indicators listed in Table A lighted during LED test?
If
YES,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
If
NO,
then continue with Step
13.
13. Are any of the indicators lighted during LED test?
If
YES,
then proceed to Step
4.
If
NO,
then continue with Step
14.
14.
!
CAUTION:
Incorrectly set ADU option switches may result in immediate or future
loss of service or may introduce errors into the digital bitstream.
Replace
ADU
with
ADU
removed previously.
15. Refer to SD-7C117-01 or SD-7C117-02. Repeat procedure from Step
1
after
locating and correcting trouble.