Power Up: DLP-501 363-205-401
Page 2 of 4 Issue 7, March 1997
12. Check wiring on rear of power shelf using SD-7C119-01 and check AC power
connections at dual bank assembly. Repeat procedure from Step
4
after locat-
ing and correcting trouble.
13. Remove DMM test leads from
LDU
.
14. Is ED7C613-30, G2 order wire build-out resistance module to be installed?
If
YES,
then continue with Step
15.
If
NO,
then
STOP. YOU HAVE COMPLETED THIS PROCEDURE.
15. Is RT assembly installed in frame or cabinet?
If
FRAME,
then proceed to Step
17.
If
CABINET,
then continue with Step
16.
16. Insert ED7C613-30, G2 order wire build-out resistance module into slot in
LDU
faceplate and proceed to Step
18.
17. At miscellaneous pair panel, pull top of faceplate forward to expose top of unit
and insert ED7C613-30, G2 order wire build-out resistance module into slot
located in top of unit on left side.
18. Set switches on order wire build-out resistance module per engineering
records (Figure 1).
STOP. YOU HAVE COMPLETED THIS PROCEDURE.