Confirms the document's technical nature, applicability, and revision rights.
Key safety warnings and recommendations for handling and installation.
Details on integrated earth/test facilities and padlock compatibility.
Options for pressure indicators and information on extensible unit configurations.
Diagram identifying components on the front fascia of the unit.
Comprehensive technical data including electrical, environmental, and SF6 gas parameters.
Line diagrams for non-extensible configurations: single, 2, 3, 4-way.
Line diagrams for extensible configurations: single, 2, 3, 4-way.
General dimensions and weight information for the unit range.
Height specifications for non-extensible and extensible units.
Dimensional drawings for 1-way and 2-way indoor/outdoor configurations.
Dimensions for 3/4-way units and weight summary for all configurations.
Explanation of information presented on the unit's rating plate.
List of IEC standards that the Aegis 36 complies with.
Procedures for unit acceptance, inspection, and handling symbols.
Packaging dimensions and guidelines for safe forklift handling of units.
Information on the unit's centre of gravity and safe forklift operation.
Step-by-step procedure for safely removing the unit from its pallet.
Guidelines for lifting units and handling packaging materials.
Recommendations for unit storage including environmental conditions and checks.
Requirements for cable trenches, including size and depth for installation.
Minimum clearance requirements around the unit during substation installation.
Diagrams illustrating internal arc gas evacuation via the back of the unit.
Outdoor trench specifications and tread plate installation for AFLR.
Guidelines for securely fixing tread plates to maintain AFLR class rating.
Specifies ambient temperature and humidity limits for Aegis 36 units.
Advice on unit condition, condensation, and authorized personnel for testing.
Procedures for unit acceptance and checking SF6 gas pressure.
Details on floor mounting requirements, plinth quality, and anchor bolts.
Floor mounting dimensions for 1-way and 2-way units.
Floor mounting dimensions for 3-way and 4-way units.
Description of LV panels and procedures for indoor LV connections.
Procedure for making LV connections in outdoor units.
Performing basic operations and main circuit resistance tests.
Testing insulation resistance of secondary wiring at 1kV.
HV insulation resistance and power frequency tests before connecting.
Detailed test schedules and procedures for relay protection testing.
Procedures for testing current transformer polarity and ratio.
Post-cabling electrical tests and checks for VPIS/NEON indication.
Testing phase comparison, shunt trip, and auxiliary wiring.
Procedure for removing cable box front panels, including interlocks.
Procedure for removing clamps and glands for 3 single core cables.
Procedure for removing clamps and glands for single 3-core cables.
Details on bushing types, cable sizes, and plug-in type terminations.
Dimensions for cable entry areas and key connecting recommendations.
Procedure for installing single 3-core cables into the unit.
Detailed step-by-step instructions for installing 3 single core cables.
Procedure for fitting short type cable mounted CT assemblies.
Procedure for fitting long type cable mounted CT assemblies.
Information on SF6 gas handling and recovery at end of service life.
Procedure for dismantling and recycling switchgear unit components.
Details on Lucy Electric's decommissioning and disposal services.
| Rated Voltage | 36 kV |
|---|---|
| Rated Current | 630 A |
| Insulation Medium | SF6 gas |
| Frequency | 50/60 Hz |
| Protection Degree | IP54 |
| Operating Temperature | -25°C to +40°C |
| Product Type | RMU |
| Insulation Level | 70/170 kV |
| Weight | Varies depending on configuration |