EasyManua.ls Logo

Lutz MD1xL - 6 Maintenance and Servicing; 7 Repairs; 8 Disposal

Lutz MD1xL
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
13
en
0698-401 MD1xL / MD2xL - 08/2020
6. Maintenance and servicing
If the compressed air motor is missing the required power, check the following points:
Fault Cause Remedy
Airpressurenotsucient
(6bar/87psi)
• Compressed air line is leaky
• Pressure losses
• Seal or replace the compressed
air line
• Enlarge the cross-section of the
compressed air line
Airpressureuctuating • Compressed air line is leaky
•Compressedairline,mueror
airlterblocked
• Error during generation of
compressed air
• Seal or replace the compressed
air line
• Clean compressed air line,
muerorairlter
• Check air compressor
Airlteronmaintenanceunit
is dirty or blocked
• Impurities in compressed air •Cleaningtheairlter
Lack of oil in the compressed
air system
• Oiler impure or damaged • Clean, repair or replace oiler
Muerblocked • Impurities in compressed air
• Dust in the environment
•Cleanmuer
If none of the above defects is detected, the compressed air motor must be repaired.
7. Repairs
RepairsshouldonlybemadebythemanufacturerorauthorizedLutzdealers.
OnlyuseoriginalLutzPumpenspareparts.Ifothersparepartsareused,liabilityonthepartofLutz
Pumpen is obsolete.
8. Disposal
Dispose of the motor according to the locally applicable regulations.