5. Technical data
Voltage supply 18 V d.c.
Idling speed: 0-350/0-1100 rpm
Torque settings: 19+1
Forward and reverse rotation yes
Chuck clamping width max. 10 mm
Battery charging voltage 18 V d.c.
Battery charging current 1.6 A
Mains voltage for charger 230 V ~ 50 Hz
Charging time: ca. 1 hour
Battery type: NiCd/1,3 Ah
Weight 1.8 kg
Max. screw diameter: 6 mm
Sound and vibration
Sound and vibration values were measured in
accordance with EN 60745.
L
pA
sound pressure level 67.33 dB(A)
K
pA
uncertainty 3 dB
L
WA
sound power level 78.33 dB(A)
K
WA
uncertainty 3 dB
Wear ear-muffs.
The impact of noise can cause damage to hearing.
Total vibration values (vector sum of three directions)
determined in accordance with EN 60745.
Drilling in concrete
Vibration emission value a
hD
= 5.31 m/s
2
K uncertainty = 1,5 m/s
2
Screwing without hammer action
Vibration emission value a
h
2,5 m/s
2
K uncertainty = 1,5 m/s
2
Additional information for electric power tools
Warning!
The specified vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equipment
is used and may exceed the specified value in
exceptional circumstances.
The specified vibration value can be used to compare
the equipment with other electric power tools.
The specified vibration value can be used for initial
assessment of a harmful effect.
Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect working
order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever
necessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain residual
risks cannot be rules out. The following hazards
may arise in connection with the equipment’s
construction and layout:
1. Lung damage if no suitable protective dust mask
is used.
2. Damage to hearing if no suitable ear protection is
used.
3. Health damage caused by hand-arm vibrations if
the equipment is used over a prolonged period or
is not properly guided and maintained.
6. Before starting the equipment
Be sure to read the following information before you
use your cordless screwdriver for the first time:
1. Charge the battery pack only with the charger
supplied.
2. Only ever use sharp drill bits and screwdriver bits
which are suitable for the purpose and in
faultless condition.
3. Always check for concealed electric cables and
gas and water pipes when drilling and screwing
in walls.