363659-LTG-D-0409
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
TECHNICAL GUIDE
GAS-FIRED RESIDENTIAL
SINGLE STAGE MULTI-POSITION
GAS FURNACES
STANDARD &Low NOx MODELS
MODELS: TG8S / TGLS
NATURAL GAS
40 - 130 MBH INPUT
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.
Standard 5-year limited Parts warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
EFFICIENCY
RATING
CERTIFIED
ISO 9001
Certified Quality
Management System
DESCRIPTION
These compact units employ induced combustion, reliable hot
surface ignition and high heat transferaluminized tubular heat
exchangers. The units are factory shipped for installation in
upflow or horizontal applications and may be converted for
downflow applications.
These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.
These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.
FEATURES
Easily applied in upflow, horizontal left or right, or downflow
installation with minimal conversion necessary.
Compact, easy to install, ideal height 33" tall cabinet.
Blower-off delay for cooling SEER improvement.
Easy access to controls to connect power/control wiring.
Built-in, high level self diagnostics with fault code displays
standard on integrated control module for reliable opera-
tion.
Low unit amp requirement for easy replacement applica-
tion.
Single wire twinning or staging feature available.
All models are convertable to use propane (LP) gas.
Electronic Hot Surface Ignition saves fuel cost with
increased dependability and reliability.
100% shut off main gas valve for extra safety.
4 speed, direct drive PSC motor.
24V, 40 VA control transformer and blower relay supplied
for add-on cooling.
Hi-tech tubular aluminized steel primary heat exchanger.
Timed on, adjustable off blower capability for maximum
comfort.
Blower door safety switch.
Solid removable bottom panel allows easy conversion.
Low NOx models have been designed to meet specific
code requirements.
Airflow leakage less than 1% of total airflow at ductblaster
conditions.
No knockouts to deal with, making installation easier.
Movable duct connector flanges for application flexibility.
Quiet inducer operation.
Inducer rotates for easy conversion of venting options.
Fully supported blower assembly for easy access and
removal of blower.
External air filters used for maximum flexibility in meeting
customers IAQ needs.
Venting applications - may be installed as a common vent
with other gas-fired appliances or use a masonry chimney.
1/4 turn knobs provided for easy door removal.
Question and Answer IconNeed help?

Do you have a question about the Luxaire TG8S and is the answer not in the manual?

Luxaire TG8S Specifications

General IconGeneral
BrandLuxaire
ModelTG8S
CategoryFurnace
LanguageEnglish

Summary

Product Overview and Features

Description

Overview of furnace features including induced combustion, ignition, heat exchangers, and installation.

Features

Lists key attributes like installation flexibility, diagnostics, ignition, and safety features.

Warranty Information

Details limited warranties for heat exchanger and parts, including extended options.

Physical Specifications

Cabinet and Duct Dimensions

Provides dimensions for furnace cabinets and duct connections across various models.

Ratings and Electrical Data

Tabulates input, output, AFUE, blower specs, and electrical data for different furnace models.

Installation and Venting Guidelines

Horizontal Sidewall Venting

Guidance on horizontal venting applications using auxiliary power vents.

Filter Performance and Requirements

Information on filter requirements and airflow capacity without filters.

Unit Clearances to Combustibles

Specifies required clearances for furnace installation near combustible materials.

Available Accessories

Propane (LP) Conversion Kit

Details kits for converting natural gas units to propane (LP) operation.

Filter Racks

Lists side and bottom return filter rack options for different cabinet sizes.

Combustible Floor Base Kit

Describes kits required for installing furnaces on combustible flooring in downflow.

EAC Transition Kits

Kits for integrating Electronic Air Cleaners (EAC) with furnace return airflow.

Masonry Chimney Kits

Kits for venting furnaces using existing or new lined masonry chimneys.

High Altitude Pressure Switches

Pressure switch kits for furnaces installed at high altitudes.

Room Thermostats

Overview of compatible thermostats for optimal performance and features.

Blower Performance Data

Bottom Return Performance

Airflow data (SCFM) for bottom return configurations across various speeds and static pressures.

Left Side Return Performance

Airflow data (SCFM) for left side return configurations across speeds and static pressures.