EasyManua.ls Logo

Luxaire THRD18S41S1 - User Manual

Luxaire THRD18S41S1
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TECHNICAL GUIDE
COMPETITOR SERIES
SPLIT-SYSTEM
HEAT PUMPS
13 SEER – R-410A
MODELS:
THRD18 THRU 60
(1.5 THRU 5 NOMINAL TONS, 1 PHASE)
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
LISTED
ISO 9001
Certified Quality
Management System
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
445073-LTG-A-0109
DESCRIPTION
The heat pump condensing unit is the outdoor part of a versatile
system of heating and air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, with each serving a specific function. Matching Air
Handlers are available for upflow, downflow, or horizontal appli-
cations to provide a complete system. Electric Heaters are
available, if required. Add-on coils are available for use with
upflow, downflow, or horizontal furnaces and air handlers.
WARRANTY
Single Phase Units:
5-year limited parts warranty.
5-year limited compressor warranty.
FEATURES
QUALITY CONDENSER COILS - The coil is constructed of
copper tubing and enhanced aluminum fins for increased
efficiency and corrosion protection.
PROTECTED COMPRESSOR - The compressor is inter-
nally protected against high pressure, temperature, and
externally by a factory installed high pressure switch. This is
accomplished by the simultaneous operation of high pres-
sure relief valve and a temperature sensor which protects the
compressor if undesirable operating conditions occur. A liq-
uid line filter-drier further protects the compressor.
DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated galvanized steel provides a better
paint to steel bond, which resists corrosion and rust creep.
Special primer formulas and matted-textured finish insure
less fading when exposed to sunlight.
LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
TOP DISCHARGE - The warm air from the top mounted fan
is blown up away from the structure and any landscaping.
This allows compact location on multi-unit applications.
LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise away from the living area.
The rigid top panel effectively isolates any motor sound. Iso-
lator mounted compressor and the rippled fins of the con-
denser coil muffle the normal fan motor and compressor
operating sounds.
LOW MAINTENANCE - Long life permanently lubricated
motor-bearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant con-
nections, and a single panel covering the electrical controls
make for easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable service
valves are provided on both the liquid and vapor sweat con-
nections for ease of evacuating and charging.
U.L. and C.U.L. listed - approved for outdoor application.
Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment cerification program, which is
based on ARI Standard 210/240.
Question and Answer IconNeed help?

Do you have a question about the Luxaire THRD18S41S1 and is the answer not in the manual?

Summary

Product Overview

Description and Warranty

Overview of the heat pump unit, its features, and warranty terms for single-phase units.

Key Features

Highlights important features like compressor protection, low cost, and sound reduction.

Physical and Electrical Data

Specifications

Details electrical ratings, compressor/fan motor specs, dimensions, and refrigerant connections.

System Configuration and Charging

Refrigerant Charge and Installation Procedures

Guidance on R-410A charge, orifice sizing, and installation procedures for optimal performance.

Cooling Capacity Data

With Air Handlers

Cooling performance data (MBH, SEER, EER) for units matched with various air handler models.

Cooling Capacity with Variable Speed Furnaces

13 SEER HP Performance

Cooling performance data for 13 SEER HP units matched with variable speed furnaces.

Heating Performance with Air Handlers

13 SEER HP Performance

Heating performance data (MBH, COP, KW, HSPF) for 13 SEER HP units with air handler models.

Heating Performance with Furnaces

With Upflow, Downflow, Horizontal Furnaces

Heating performance data for units matched with various furnace types.

With Variable Speed Furnaces

Heating performance data for units matched with variable speed furnace models.

Accessories and Sound Ratings

Optional Accessories and Controls

Details on optional kits, controls, and thermostats for system enhancement and operation.

Sound Power Ratings

Presents sound power ratings in dBA for cooling and heating modes by unit model.

Installation and Wiring

Installation Guidelines

Provides required clearances and notes for proper outdoor unit installation.

Field Wiring Diagrams

Illustrates typical electrical connections for thermostat, indoor and outdoor units.

Luxaire THRD18S41S1 Specifications

General IconGeneral
ModelTHRD18S41S1
TypeHeat Pump
Cooling Capacity1.5 Tons (18, 000 BTU/h)
Heating Capacity1.5 Tons (18, 000 BTU/h)
SEER Rating14.5
HSPF Rating8.2
Voltage208/230 V
Phase1
RefrigerantR-410A

Related product manuals