Fig. 2 Diagnostics – errors detected
E1 - (Error) – internal defect of the microprocessor
controller
E2 - (Error) – damaging to a power board of the regulator
E3 - (Error) – short circuit on the line / pressing the (-)
button
E4 - (Error) – short circuit on the line / pressing the (+)
button
E5 - (Error) – short circuit on the line / pressing the STOP
button
E6 - (Warning) – deleting the controller configuration
settings
Once the auto-diagnostic sequence has terminated,
the regulator switches into normal operation mode –
awaiting the start-up. “0” appears on the display, which
signals rotation deactivation. Rotation activation occurs by
pressing the plus button. .
First pressing of the plus button (switching from “0”
index to “1” index) triggers the start-up procedure. The
regulator shall start with adequately increased power in
order to decrease the power until the level adjusted by the
first step of the settings. The regulator switches into normal
operating mode, signalling the selected speed index in the
following manner: .
Fig. 3 Extracting – speed setting
Subsequent pressing / holding down the pressed plus or
minus button shall change the engine rotational speed.
Deactivation of the rotations is performed by the minus
button (downgrading to “0” index) or by pressing the STOP
button.
Detection of the honey extractor lid opening or
pressing the emergency stop button will bring about the
deactivation of the engine rotations and the flashing symbol
specified below shall appear on the display
Fig. 4 Open honey extractor lid, EMG STOP button
pressed
SDD-2DP controller has been equipped with Auto OFF
function – it switches off the engine rotations after 15
minutes from the last pressing of the plus or minus buttons
SDD-2DP controller may be equipped with thermal
protection function – it disconnects the engine power supply
when the thermal protection sensor or the thermostat
contacts are open. Triggering the protection is signalled by
“Ht” message
5. Storing the honey extractors
Once the honey harvesting has terminated the device is to
be washed thoroughly.
Prior to the honey extractor start-up, in case when it has
been transferred from a room with a lower ambient
temperature to a room with a higher one , one must wait
until the device has reached the ambient temperature.
The device is to be stored in dry rooms with the
temperature above 0º C.
Before every season, an additional technical inspection
must be performed and n case when any defects have been
detected , a service centre must be contacted.