Table 3: For SAE O-Ring Boss (Steel) & Gates Adapterless
Size
Ft-Lbs.
Working Pressures
4,000 psi (27.5 Mpa)
and below
Newton-Meters
Working Pressures
4,000 psi (27.5 Mpa)
and below
Ft-Lbs.
Working Pressures
Above 4,000 psi (27.5
Mpa)
Newton-Meters
Working Pressures
Above 4,000 psi (27.5
Mpa)
Dash
Fractional
(In.)
Min. Max. Min. Max. Min. Max. Min. Max.
-3 3/16 ––––8101113
-4 1/41416202214162
022
-5 5/16
––––18 20 24 27
-6 3/82426333524263
335
-8 1/23744506050606
878
-105/8 5060688172809
8110
-12 3/4 75 83 101-1/2 113 125 135 170 183
-14 7/8
––––160 180 215 245
-16 1 111 125 150 170 200 220 270 300
-20 1-1/4 133 152 180 206 210 280 285 380
-24 1-1/2 156 184 212 250 270 360 370 490
Table 4: Maximum Recommended Torque for dry NPTF (Tapered) Pipe Threads*
sreteM-notweN.sbL-tFeziS
52022-
53524-
54536-
06548-
575521-
095661-
0110802-
0315942-
06102123-
*NOTES:
1. The torque values obtained from tightening pipe threads can vary considerably
depending on thread condition. Adequate sealing can occur at values much lower than
the maximum values listed above. Only enough torque to achieve adequate sealing
should be used.
2. When using a male tapered pipe thread with a female straight or parallel pipe thread,
maximum values are 50% of those listed in the table.
3. If threaded sealant is used, maximum values shown should be decreased by 25%
M-B Multi-Service Vehicle • 103 • Service
©2015 M-B Companies Inc.
All Rights Reserved