manual utilizare presostat electronic
pressystem
46
07
(Vers.Cosφ)
- Lipsa apa
- Dry running
Valoarea cosφ masurata de
PresSystem este inferioara
pragului setat (LED COSφ).
Ce trebuie facut:
1. Pentru a reporni
sistemul si a iesi din eroare
trebuie apasat butonul ON/OFF
pana se afiseaza “OF”.
2. Apasati din nou
butonul ON/OFF pentru a
reporni dispozitivul.
SOLUTII:
Verificati prezenta efectiva a
apei in instalatie
Asigurati-va ca nu exista
bule de aer in instalatie
Verificati amorsarea corecta
a pompei
Daca aveti instalat un filtru,
verificati ca acesta sa nu fie
blocat de impuritati.
The value of cosφ measured is
below than the threshold set on
PresSystem (LED COSφ).
ACTIONS:
1. To restart the system and
exit from the error you must
press the ON/OFF button to
display "OF".
2. Press again ON/OFF button
to restart the system.
SOLUTIONS:
Check for water presence
Check there is no air in the
system
Reset the correct priming
pump function
If there is a filter, check if it is
blocked
08
- Eroare
setare
parametru
- Parameter
error
Aceasta eroare indica faptul
utilizatorul a setat manual
presiunea minima dar presiunea
maxima inca este administrata
automat de catre PresSystem.
Ce trebuie facut:
1. Pentru a reporni
sistemul si a iesi din eroare
trebuie apasat butonul ON/OFF
pana se afiseaza “OF”.
2. Apasati din nou
butonul ON/OFF pentru a
reporni dispozitivul.
SOLUTII:
Verificati ca presiunea
minima setata manual este
The error indicates that the user
has manually changed the restart
pressure and the maximum
pressure is still handled
automatically by the device.
ACTIONS:
1. To restart the system and
exit from the error you must
press the ON/OFF button to
display "OF".
2. Press again ON/OFF button
to restart the system.
SOLUTIONS:
Check that the restart