- 22 - - 23 -
Inspection and checking intervals
Demonstrable initial check
6-18 months aer installation;
thereaer, every 3-5 years
for private use or every
6-18 months for commercial use
(depending on the load intensity)
End Users
Specialist
Check the xing screws and, if
necessary, tighten or replace.
✘ ✔
Set or check the contact pressure
of the locking points, and if
necessary adjust.
✘ ✔
ATTENTION!
✘ = may ONLY be carried out by a SPECIALIST, and NEVER by the
end user!
Hinging the door in and out, as well as any adjustment of the
hardware must only be carried out by a specialist! Maintenance of
safety-relevant parts (hinges) may also only be carried out by a
specialist!!
The hardware on your door must be actuated at least once a month
to prevent so-called „dormant wear“.
Lubrication points
› This representation is only symbolic. The position and number of
lubrication points depends on the actual size and model of the
door!
› Grease for hardware:
Adhesive lubricant with PTFE in a spray, e.g. OKS 3751 or
equivalent (Haberkorn Company Art. Nr. 79937).
› Amount of Lubricant:
approx. 3 mm³ (≈ size of a pinhead)
› Aer lubrication, the hardware must be operated several times to
distribute the lubricant.