010-200002-000 Page 1 HB IOM 1.1 2-13-2014
AIR HANDLERS AND FAN
COILS
t ĂƌƌĂŶƚLJZĞŐŝƐƚƌĂƟŽŶĂŶĚĂƌƚ-up Report
Warranty Registration Form: Complete
and submit this form within ten (10) days of
start-up to comply with the terms of the
Magic Aire warranty. Form must be com-
pleted to clearly indicate startup for each
unit being registered.
Mail form(s) to Magic Aire
Warranty Department
501 Galveston St.
Wichita Falls, TX, 76301 or
Email customer.service@MagicAire.com
STARTUP REPORT
Group Checklist Item Yes No
Electrical/Operational
Have red shipping screws been removed from blower discharge?
Does electrical service correspond to unit nameplate?
-Nameplate Supply Voltage/Phase: Rated_________ Measured___________
-Nameplate Rated FLA motor current: Rated_______ Measured__________
Does all field wiring conform to unit wiring diagram?
Is field-provided freeze protection present? (for DX and hydronic coils)
Is fan wheel turning the correct direction?
Are mixing box dampers operating properly?
Is the filter clean?
Structural
Is unit properly supported?
Is unit installed level (necessary for proper condensate drainage)?
Is properly sized condensate trap present?
Is the condensate disposal system operating correctly?
Is auxiliary external condensate drain pan installed as recommended by IOM? (not
required for valid warranty)
DX Sys-
tems
Is expansion valve sensing bulb properly installed and insulated?
Is Heat Pump Bypass Kit (HPK) present if required?
Is the DX system charged per the condensing unit mfr’s instructions?
Piping
Check
Is unit piping correct and insulated to prevent condensation?
Are the control valve packages piped correctly?
Are Valve packages properly insulated?
Are there any leaks detected: interior to unit, at connections, or at valve packages?
Hydronic
Systems
Have customer-provided Freeze Protection measures been taken, such as Low
Limit Thermostats and glycol (antifreeze) heat transfer fluids?
Does the hydronic system include a pressure relief valve or other pressure relief
device to protect the coil from operating pressures beyond the nameplate design
working pressure rating?
Are coils equipped with control valves to stop fluid flow to save energy and prevent
cabinet condensation (wild coil in cooling) when heating/cooling is not required?
Does setting for overload device (factory or field-provided) match motor FLA?
Job Name City
Sales Order # Unit Tag
Model Number Serial Number
Installer Quantity of Units

Other manuals for Magic Aire HB Series

Question and Answer IconNeed help?

Do you have a question about the Magic Aire HB Series and is the answer not in the manual?

Magic Aire HB Series Specifications

General IconGeneral
BrandMagic Aire
ModelHB Series
CategoryAir Handlers
LanguageEnglish

Related product manuals