If the 2-stage shock sensor triggered ---- LED is in the cycle of flashing once and off.
If truck or hood triggered ------------------ LED is in the cycle of flashing twice and off.
If doors triggered ---------------------------- LED is in the cycle of flashing three times and off.
If ignition triggered -------------------------- LED is in the cycle of flashing four times and off.
C. Clean trigger memories: Press button to disarm, and then switch the ignition on to clean trigger memories.
3.7 ALARM:
A. 1st-stage Shock Sensor Trigger:
Under the arm mode, the siren will chirp three times when triggered. If three constant triggers are the first-stage ones, then the
first-stage shock sensor will be bypassed until the system is back
B. 2
nd
-stage Shock Sensor Trigger:
Under the arm mode, the siren will sound for 30 seconds when triggered. Lights will flash 30 seconds, LED is in the cycle of
flashing once and off, the system will be back to the arm mode after 30 seconds. If three constant triggers are the second-stage ones,
then the second-stage shock sensor will be bypassed until the system is back to the arm mode.
C. Truck or hood Trigger
a. Under the arm mode, the siren will sound for 30 seconds if truck or hood is triggered. The siren will sound for 30 second
s,
lights will flash 30 seconds, LED is in the cycle of flashing twice and off, the system will be back to the arm mode after 30
seconds
.
b. Und
er the arm mode, if truck or hood is triggered and then are still opened, the siren will alarm for three cycles and th
e
b
etween interval is 3 seconds. The system will be still in the arm mode then the sensors of truck or hood will be bypassed unti
l
they are cl
osed
properly
D. Door Trigger
a. Under the arm mode, the system will alarm if doors are triggered. The siren will sound for 30 seconds, lights will flash 30
seconds, LED is in cycle of flashing three times and off, the system will still be under the arm mode
.
b. Und
er the arm mode, the system will alarm for 3 cycles if doors are triggered and still opened. The between interv
al is 3
seconds
. After 3 alarm cycles, the system is still under the arm mode. The door sensors will be bypassed until doors are closed
properly.
E. Ignition T
rigger
a. Under the arm mode, if the ignition is triggered, the siren will sound for 30 seconds, LED is in the cycle of flashing four tim
es
an
d off, the system will still be under the arm mode
.
b. Und
er the arm mode, if the ignition is triggered and is still on, the system will alarm for 3 cycles and the between interval i
s 3
seconds. After 3 alarm cycles, the system is still under the arm mode. The ignition sensor will be bypassed until the ignition is
off.
F
. Alarm Disable:
a. The system will be still under the arm mode after the 30-second alarm ti
me
b. During
the alarm, press button (2) once, the system will be under the disarm mode. The siren will chirp 4 times, the start-kill
is
on, lights flash three times, doors unlock and the LED will flash trigger memories.
3.8 Trunk Release
Under any situation, press button (3) over 2 seconds, the truck will be released.
3.9 Panic Mode
a. Under the arm or alarm mode, press button (1) over 3 seconds, the system will be armed. 3 seconds later, star-kill will be on
and door lock. The siren will sound for 30 seconds, lights will flash for 30 seconds and LED flashes rapidly. The system will
still be under the arm mode after 30 second
s.
b. Und
er the disarm mode, press button (2) over 3 seconds, the system will be armed. 3 seconds later, the siren will sound
for
3
0 seconds, lights flash 30 seconds. LED flashes rapidly. The system will still be under the arm mode after 30 seco
nds.
c. Und
er the arm mode, press button (4) once, the siren will sound 30 seconds, lights will flash 30 seconds, LED flash rapidly.
The system will still be under the arm mode after 30 seconds.
d. Und
er the disarm mode, press button (4) once, the alarm will sound for 30 seconds, start-kill is on, door will be locked, light
s
flash
30 seconds and LED flashes rapidly. The system will still be under the arm mode after 30 seco
nds.