Questions and Answers

  • N
    Nancy DavisSep 23, 2025
    Why is the current assurance light defective on Magnaflux Industrial Electrical?
    • L
      Linda MarshallSep 23, 2025
      If the current assurance light on your Magnaflux Industrial Electrical unit is defective, replace the ammeter.
  • A
    Angel ShannonAug 23, 2025
    What to do if there's a continuous mag shot on my Magnaflux Industrial Electrical coil?
    • A
      Amy TurnerAug 25, 2025
      If you're experiencing continuous mag shots on the coil or contact of your Magnaflux Industrial Electrical unit, it's likely due to a shorted SCR. You should call an Authorized Service Center.
  • S
    spierceAug 25, 2025
    How to troubleshoot no line voltage on Magnaflux Industrial Electrical?
    • A
      Austin WatkinsAug 26, 2025
      If your Magnaflux Industrial Electrical unit shows no line voltage and the green power indicator light is off, here's what to check: * Ensure the external fused disconnect switch is on. * Replace the fuse in the external disconnect switch if it's blown, and check for shorts if it continues to blow. * Replace fuse 1FU, and check for shorts if it continues to blow. * Replace the green power indicator lamp if it's burned out.
  • T
    Toni BrowningAug 27, 2025
    Why is the output current low on my Magnaflux Industrial Electrical unit?
    • T
      timothykimAug 27, 2025
      To resolve low output current at higher current control settings on your Magnaflux Industrial Electrical equipment: 1. Check the equipment output with a central conductor (optional accessory). If the output is within specifications, the part cannot be tested with this equipment. 2. Check the line voltage and correct it if possible, or try another line. 3. Clean connections and tighten hardware. 4. Adjust the voltage range on the current controls as per instructions. 5. If you have MOD AC (Optional), check the SPAN and BIAS adjustments on the AC firing board.
  • H
    Hayley Ruiz DDSAug 27, 2025
    How to fix irregular current through contacts on Magnaflux Industrial Electrical?
    • R
      Rose RosarioAug 28, 2025
      If your Magnaflux Industrial Electrical unit has no output current or irregular current through the contacts, follow these steps: 1. Clean connections and tighten hardware at bus bars or cable joints. 2. Replace fuse 5FU. Check for shorts if the fuse continues to blow. 3. Swap relays 5CR and 6CR. 4. Check outputs on the PLC and see if Output 2 is off during COIL mag shot and Output 2 is on during CONTACTS shot. Check harnesses and replace or repair as necessary. 5. Call Authorized Service Center.
  • K
    Kelly AllenSep 17, 2025
    Why is the meter not lighting up on my Magnaflux Industrial Electrical unit?
    • P
      Pamela RomeroSep 18, 2025
      If the meter on your Magnaflux Industrial Electrical unit doesn't light up: 1. Replace fuse 6FU. Check for shorts if the fuse continues to blow. 2. Check harnesses and replace or fix as necessary. 3. Check cables for worn indication. Replace the meter if necessary due to a surge.
  • A
    Amanda AdkinsSep 14, 2025
    How to fix white light not working on Magnaflux Industrial Electrical?
    • Z
      zcamachoSep 14, 2025
      If the white light on your Magnaflux Industrial Electrical unit does not work: 1. Replace the bulb. 2. Replace fuse 3FU. Check for shorts if the fuse continues to blow. 3. Check the white light switch and replace it if defective. 4. Replace 3CR.
  • C
    Charles MccormickSep 15, 2025
    What to do if the meter doesn't work on Magnaflux Industrial Electrical?
    • M
      Michelle WintersSep 16, 2025
      If the meter on your Magnaflux Industrial Electrical unit does not work: 1. Connect an oscilloscope to terminal 5 & 6 on the meter (at 50MV/DIV). At 2,000 amps, the waveform should be approximately 2 divisions (0 to peak). If the waveform is not there, check the harness. 2. Replace the meter if it got wet.
  • S
    shortsarahSep 6, 2025
    How to fix irregular clamping action on Magnaflux Industrial Electrical?
    • J
      jsmithSep 6, 2025
      If you are experiencing irregular clamping action at the headstock of your Magnaflux Industrial Electrical unit: 1. Clean or replace the pressure regulator. 2. Clean the air filter.
  • S
    Scott CarpenterSep 3, 2025
    Why is the demagnetization not working on my Magnaflux Industrial Electrical unit?
    • C
      Crystal DunnSep 3, 2025
      If the demag function on your Magnaflux Industrial Electrical unit isn't working or doesn't completely demagnetize: 1. Call Authorized Service Center to check if the SCR is not properly balanced. 2. Change 1 cap.