www.magnaflux.com
Y-7 AC/DC Yoke Operating Instructions
The Y-7 is an articulating leg magnetic yoke providing A.C. or D.C. magnetic fields for defect detection in
ferromagnetic materials. The Y-7 has the capability of demagnetization, if required.
Specifications:
Power Source: The Y-7 is configured for 115 volt, 50/60Hz.1 phase, OR 220 volt, 50 Hz.1 phase.
Current Draw: 115V version - 4 amps / 230V version - 2 amps.
Mechanical Capacity: Minimum-maximum distance across poles: 1“ to 12".
Magnetic Field: A.C: Constant level. D.C: Pulsed.
Pull Force: The Magnaflux Y-7 yoke is designed to lift 10 lbs or 40 lbs as specified in
ASTM E-444. Please refer to this specification for more details.
Yoke Weight: 7.7 pounds.
Controls: Electronic - Solid state contained within the housing.
Manual: Momentary, push to test switch A.C./D.C. selector switch
Duty Cycle: 33% with 80 seconds "ON" maximum.
Caution!
1. DO NOT connect the power cord to a battery for portable work-power source must be as
noted on the nameplate.
2. DO NOT change the AC/DC selector switch while the unit is energized.
Question and Answer IconNeed help?

Do you have a question about the Magnaflux Y-7 and is the answer not in the manual?

Magnaflux Y-7 Specifications

General IconGeneral
BrandMagnaflux
ModelY-7
CategoryCables and connectors
LanguageEnglish

Summary

Y-7 AC/DC Yoke Specifications

Power and Current Details

Specifies voltage, phase, and current draw for different versions.

Mechanical and Field Characteristics

Covers pole distance, pull force, weight, and magnetic field type.

Controls and Duty Cycle

Details electronic controls, manual switch, and recommended duty cycle.

Y-7 AC/DC Yoke Operation Principles

Principle of Operation

Explains how the yoke generates a magnetic field and detects flaws.

Magnetizing Field Selection

Differentiates AC (surface) and DC (subsurface) magnetization.

Inspection Procedure

Covers positioning, energizing, and applying inspection particles.

Demagnetization Process

Details how to use the yoke for demagnetizing parts.