Specifications and Site Requirements
Electrical Specifications
44 MagneMotion
Rockwell Automation Publication MMI-UM002E-EN-P - March 2016
MM LITE Power Supply
100 - 240 VAC @ 50 - 60 Hz, single phase (phase to phase or phase to neutral), 8.5 A based
on configuration and operating mode. Inrush current 35 A/110 VAC, 70 A/220 VAC max.
Refer to MM LITE Power Supply on page 4-25 for the mechanical drawing.
The actual power being drawn depends upon operations being performed, however all power
wiring must be capable of carrying the full load.
Each MM LITE Power Supply provides two 300W DC outputs for powering the MM LITE
motors. The number of power supplies required for a specific MM LITE configuration can be
determined from Table 4-1 where the maximum power consumption for each component
within the MagneMover LITE transport system is identified.
NOTE: MagneMotion recommends that no more than 20 motors be powered from a single
MM LITE Power supply (10 per 300W DC output).
CAUTION
High Voltage Hazard
100 - 240 VAC, 8.5 A
AC power must be disconnected before servicing.
CAUTION
Double Pole/Neutral Fused
AC power must be disconnected before servicing.
NOTICE
The MM LITE Power Supply uses an internal NRTL/ATL approved power
source. If a user-supplied power supply is used in its place it must be
NRTL/ATL approved.