Version with humidity control and timer
This version is equipped with timer and humidistat. See
the preceding point for the functioning of the timer.
To adjust the humidistat, regulate the adjustment trim-
mer (screw) illustrated in the figure to increase or de-
creasethehumiditythresholdthatmakestheappliance
intervene automatically. The humidity sensor is adjust-
able from 40% to 90% of Relative Humidity.
It is possible to control the appliance from a remote
switch if it is connected as indicated in figure 10/3.
IMPORTANT: it is not possible to switch off the ap-
pliance by the remote switch if the level of environ-
mental humidity is more than the set threshold.
Troubleshooting
PROBLEM CAUSE AND REMEDY
The appliance does not
switch on
There is no voltage.
Checkthemainswitchand/
or the electrical connections.
The impeller does not turn Check that its movement is
not slowed down.
Versions
Standard
Version with timer
Adjustthetrimmer(screw)illustratedintheguretoin-
crease or decrease the delay in turning off the device
(from 3 to 25 minutes).