Installation Instructions and
Homeowners Manual
INSTALLER: DO NOT DISCARD THIS MANUAL - LEAVE FOR HOMEOWNER
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
Do not use any phone in your
building.
Immediately call your gas supplier
from your neighbor's phone. Follow
the gas suppliers instructions.
If you cannot reach your gas
supplier call the fire department.
INSTALLER/CONSUMER
SAFETY INFORMATION
Chateau™
Direct Vent Decorative
Gas Appliance
Model: DVT38, DVT44
CERTIFIED
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
20006081 7/04 Rev.5
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
CFM Specialty Home Products

Table of Contents

Questions and Answers

  • C
    crystalcruzAug 1, 2025
    Why won't the pilot light stay lit on my Majestic Indoor Fireplace?
    • J
      Jamie PhelpsAug 1, 2025
      If the pilot light on your Majestic Indoor Fireplace won't stay lit after following the lighting instructions, there could be a few reasons. First, the pilot generator (thermocouple) or remote wall switch might be defective. Ensure the pilot flame is properly hitting the thermocouple/thermopile. Clean and adjust the pilot for maximum flame impingement on the thermopile and thermocouple. Also, the automatic valve could be defective. To check this, turn the valve knob to “Pilot” and maintain flow to pilot; a millivolt meter should read greater than 10mV. If the reading is okay but the pilot still doesn’t stay on, the gas valve should be replaced. Note that an interrupter block (not supplied) must be used to conduct this test.
  • K
    Kirsten HortonAug 8, 2025
    How to fix a Majestic Indoor Fireplace spark ignitor that won't light?
    • J
      jacquelinebryantAug 8, 2025
      If your Majestic Indoor Fireplace spark ignitor won't light, it could be due to a defective or misaligned electrode at the pilot. Try lighting the pilot with a match. If it lights, turn off the pilot and push the red button again. If it still doesn't light, check the gap at the electrode and pilot; it should be 1/8” for a strong spark. Another possibility is a defective ignitor (push button). With the control knob in the pilot position, push the control knob all the way and hold. Check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the battery in the ignitor module and try again. If the problem persists, replace the ignitor module box.
  • S
    Steven ThomasAug 25, 2025
    Why does my Majestic Indoor Fireplace have frequent pilot outage problems?
    • D
      Daisy RogersAug 25, 2025
      Frequent pilot outages in your Majestic Indoor Fireplace can be caused by a pilot flame that is too low or blowing too high, causing the pilot safety to drop out. Clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermopile and thermocouple. Also, check the vent terminal for any blockage that might be recycling the flue gases.
  • D
    Deanna ScottNov 15, 2025
    What to do if my Majestic Indoor Fireplace pilot is burning but there's no gas to the main burner?
    • U
      ubrownNov 15, 2025
      If the pilot light is burning on your Majestic Indoor Fireplace, but no gas is reaching the main burner, several issues could be the cause. The wall switch or its wires might be defective; check them for proper connections. You can use a jumper wire across the terminals at the wall switch. If the burner comes on, replace the defective wall switch. If it's still not working, jumper the wires across the wall switch wires at the valve. If the burner then comes on, the wires are faulty or the connections are bad. Another potential issue is that the thermopile may not be generating enough millivoltage. Ensure the wire connections from the thermopile at the gas valve terminals are tight and that the thermopile is fully inserted into the pilot bracket. Also, check if one of the wall switch wires ...

Summary

Installer and Consumer Safety Information

General Safety Precautions

Key safety information and warnings for installation and operation.

Installation and Operating Instructions

Clearance to Combustibles and Mantels

Guidelines for clearances to combustible materials, mantels, and hearth.

Gas Specifications and Line Installation

Details on gas specifications, pressure, high elevations, and gas line setup.

General Venting Information

Venting Overview and Termination Location

Principles of venting and guidelines for vent termination placement.

Lighting and Operating Instructions

Standing Pilot Lighting Procedure

Step-by-step guide for lighting the pilot on standing pilot models.

Electronic Ignition Lighting Procedure

Step-by-step guide for lighting the pilot on electronic ignition models.

Troubleshooting the Gas Control System

SIT NOVA 820 Millivolt Valve Issues

Common problems and corrective actions for the SIT NOVA 820 millivolt gas control valve.

SIT 822 Electronic Ignitor Troubleshooting

Troubleshooting flowcharts for electronic ignition systems with SIT 822 valve.

Fuel Conversion Instructions

Conversion Precautions and Procedure

Safety warnings and steps for converting the appliance between fuel types.

Injector Orifice Size Matrix

Limited Lifetime Warranty