EasyManua.ls Logo

Majestic RHEDV25 - User Manual

Majestic RHEDV25
38 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
10000801 5/03 Rev. 4
Installation and service must be performed
by a qualified installer, service agency or
your gas supplier.
FOR YOUR SAFETY
DO NOT STORE
OR USE GASOLINE OR OTHER
FLAMMABLE VAPOURS AND LIQUIDS
IN THE VICINITY OF THIS OR ANY
OTHER APPLIANCE.
FOR YOUR SAFETY
What to Do if You Smell Gas:
Do not try to light any appliance.
Do not touch any electric switch.
Do not use any phone in your building.
Immediately call your gas supplier from your
neighbours phone. Follow the gas suppliers
instructions.
If you cannot reach your gas supplier call the
fire department.
WARNING! IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE,PERSONAL INJURY OR LOSS OF LIFE.
Installation Instructions & Homeowner's Manual
Direct Vent Insert
Models: RHEDV25
RHEDV32
RHEDV42
INSTALLER: DO NOT DISCARD THIS MANUAL - Leave For Homeowner
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
CERTIFIED
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
Vermont Castings, Majestic Products

Questions and Answers

  • D
    David JenkinsAug 19, 2025
    Why does my Majestic RHEDV25 pilot keep going out?
    • X
      xjonesAug 19, 2025
      If you're experiencing frequent pilot outages with your Majestic Indoor Fireplace, consider these potential causes: * The pilot flame might be too low or too high, causing the pilot safety to drop out. Clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermopile and thermocouple. * There might be a blockage in the vent terminal, causing the flue gases to recycle. Check the vent terminal for any obstructions.
  • J
    Juan RomanAug 27, 2025
    What to do if Majestic RHEDV25 pilot will not stay lit?
    • P
      Pamela LeeAug 27, 2025
      If the pilot light on your Majestic Indoor Fireplace won't stay lit even after following the lighting instructions, consider these possibilities: * The pilot generator (thermocouple) or remote wall switch may be defective. Ensure the pilot flame properly impinges on the thermocouple. Clean or adjust the pilot for optimal flame impingement on the thermopile and thermocouple. * The automatic valve might be defective. Turn the valve knob to 'Pilot' and maintain flow to the pilot. A milivolt meter should show a reading greater than 10 mV. If the reading is okay but the pilot still won't stay on, replace the gas valve. Note: An interrupter block (not supplied) must be used to conduct this test.
  • K
    Kimberly DeleonSep 3, 2025
    How to fix a Majestic Indoor Fireplace spark ignitor that will not light?
    • B
      Brandon BrownSep 3, 2025
      If the spark ignitor on your Majestic Indoor Fireplace isn't lighting, try these steps: * Light the pilot manually using a match. If the pilot lights, turn it off and try pushing the red button again. If the pilot still doesn't light, check the gap at the electrode and pilot; it should be 1/8" to ensure a strong spark. * Test the ignitor button. Push the piezo ignitor button and check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, the ignitor may be defective and needs replacement.
  • G
    gomezsierraNov 11, 2025
    What to do if my Majestic Indoor Fireplace pilot is burning, but no gas goes to the main burner?
    • W
      William GoodNov 11, 2025
      If the pilot light is on but the main burner isn't getting gas, here's what to check: 1. Inspect the wall switch and wiring for solid connections. Try bypassing the wall switch by using a jumper wire across the terminals. If the burner ignites, the wall switch is likely faulty and needs replacement. If it doesn't help, try to jumper the wires across wall switch wires at the valve, and if the burner comes on, the wires are faulty or connections are bad. 2. Ensure the thermopile wire connections at the gas valve terminals are secure, and the thermopile is fully inserted into the pilot bracket. One of the wall switch wires may be grounded. Remove wall switch wires from valve terminals; if the pilot now stays lit, trace the wall switch wiring for a ground. Check the thermopile output with a...

Majestic RHEDV25 Specifications

General IconGeneral
ModelRHEDV25
CategoryIndoor Fireplace
Fuel TypeNatural Gas or Propane
FinishBlack
TypeDirect Vent
Voltage120 V
BTU Input25, 000 BTU/h
VentingDirect Vent
IgnitionElectronic
WarrantyLimited Lifetime Warranty