Resistance:
Range Accuracy Resolution
400 ±(1.0 % +2) 0.1
4k
±(0.8 % +3)
1
40k 10
400k 100
4M 1k
40M ±(2.0 % +3) 10k
Overload protection: 250V DC or AC rms.
Capacity:
Range Accuracy Resolution
50nF
±(3 % +5)
10pF
500nF 100pF
5µF
±(5 % +5)
1nF
50µF 10nF
100µF 100nF
Overload protection: 250V DC or AC rms.
Diode and Audible Continuity Test:
Function Range
1.5V
Built in buzzer sounds if resistance is
less than 50±30.
Overload protection: 250V DC or AC rms.
Frequency:
Range Accuracy Resolution
50.00Hz
±(1.0 % +5)
0.01Hz
500.0Hz 0.1Hz
5000Hz 1Hz
50.00kHz 10Hz
500.0kHz 100Hz
1.000MHz 1000Hz
The frequency range is selected by pressing the "Hz%"
key only on voltage or current range.
Sensitivity: sine wave 1.5V rms.
Duty Cycle
The duty cycle range can be selected by pressing the
"Hz%" key on alternating voltage, alternating current or
frequency range. % is shown in the display. 0.1 %~99.9
%: ±(2.0 % +2) Frequency lower than 10kHz.
Overload protection: 250V DC or AC rms.
Temperature:
Range Accuracy Resolution
ºC
50ºC~750ºC 2 % +1ºC
1ºC0ºC~50ºC ±2ºC
-55ºC~0ºC 9 % +2ºC
NiCr-NiSi sensor (K-type thermocople).
Overload protection: 0.5/250V fuse.
ELECTRICAL SPECIFICATIONS
Accuracies are ±(% of reading + number in last digit) at
23±5ºC, 75 % RH.
DC Voltage:
Range Accuracy Resolution
400mV
±(0.5 % +3)
0,1mV
4V 1mV
40V 10mV
400V 100mV
1000V ±(10 % +5) 1V
Overload protection: 1000V DC or 750V AC rms.
Impedance: 10M, more than 100M on 400mV range.
AC Voltage:
Range Accuracy Resolution
400mV ±(3.0 % +3) 0.1mV
4V
±(1.0 % +3)
1mV
40V 10mV
400V 100mV
750V ±(1.0 % +5) 1V
Frequency: 40~400Hz.
Overload protection: 1000V DC or 750V AC rms.
Impedance: 10M, more than 100m on 400mV range.
DC Current:
Range Accuracy Resolution
400µA
±(1.5 % +3)
0.1µA
4000µA 1µA
40mA 10µA
400mA 100µA
4A
±(2.0 % +3)
1mA
10A 10mA
Overload protection: 0.5A/250V fuse.
10A/250V fuse (10A up to 15 seconds).
AC Current:
Range Accuracy Resolution
400µA
±(1.5 % +3)
0.1µA
4000µA 1µA
40mA 10µA
400mA 100µA
4A
±(2.5 % +5)
1mA
10A 10mA
Frequency: 40~400Hz.
Overload protection: 0.5A/250V fuse.
10A/250V fuse (10A up to 15 seconds).