Technical data
33
Engine lubrication Force feed
Oil capacity in oil sump (litres) min. max.
deep 24 l 30 l
shallow 24 l 30 l
with yoke 33 l 39 l
Oil change quantity (with filter)
deep / shallow 33 l
with yoke 42 l
Oil pressure during operation (depend-
ing on oil temperature, oil viscosity
class and engine rpm)
must be monitored by oil pressure moni-
tors / gauges
Oil filter Full flow filter with paper cartridges
Engine cooling system Liquid cooling
Coolant temperature 80−90°C, temporarily 95°C allowed
Electrical equipment
Starter 24 V; 5,4 or 6,5 kW
Alternator 28 V; 55, 80, 100, 140 A