MALFUNZIONAMENTI, LORO CAUSE E POSSIBILI RIMEDI
Malfunzionamenti Cause Possibili rimedi
L autocentrante non ruota in alcun
senso
1. Spina di tensione non inserita
2. Non corretto collegamento della
spina
3. Tensione non conforme
4. Non è stato acceso l’interruttore
generale
5. Fusibili guasti
1. Veri care il corretto inserimento
della spina nella presa e il suo colle-
gamento 2-3 Vedi 1
4. Accendere l’interruttore generale
5. Sostituire i fusibili.
L’autocentrante gira con forza insuf-
ciente
1. Non corretta tensione di rete
2. Cinghia lenta
3. Fusibile “saltato”
1. Veri care la corrispondenza fra
la tensione di rete e quella indicata
sulla targhetta del costruttore
2. Agire sul tendicinghia
3. Sostituire Fusibile
L’autocentrante non blocca
correttamente la ruota
1. Non è stato acceso l’interruttore
magnetotermico
2. Insu ciente pressione alla rete
idraulica
3. Perdita di pressione sul circuito
idraulico
1. Assicurarsi che il motore della
centralina giri nel senso di rotazione
corretto
2. Regolare in modo consono la
pressione della rete idraulica
3. Eliminare le eventuali perdite di
pressione
La macchina (carrello, braccio o
mandrino) non fa nessun movimen-
to idraulico
1. Il motore della centralina non gira
in senso corretto
2. E’ disinserito l’interruttore magne-
totermico
3. E’ saltato un fusibile sulla 24V
1. Invertire le fasi 1-2 nella spina di
tensione
2. Inserire il magnetotermico
3. Sostituire il fusibile
MALFUNCTIONS: CAUSES AND POSSIBLE REMEDIES
Malfunction Cause Possibile remedies
The chuck does not rotate in any
direction
1. The mains connection is not plug-
ged in
2. The plug is not correctly wired
3. The mains tension is not suitable
for the machine
4. The mains switch is not on
5. Faulty fuse
1. Check the correct insertion of the
plug and its connections 2.- 3. See 1
above
4. Switch on the mains
5. Replace the fuse
The chuck turns but only weakly 1. Mains tension is incorrect
2. Loose belt
3. Fuse blown
1. Check the compatibility of mains
tension and that shown on the ma-
chine registration plate
2. Adjust the belt tightener
3. Replace the fuse
The chuck does not lock the wheel
correctly
1. The thermomagnetic switch is not
on
2. Insu cient pressure in the
hydraulic circuit
3. Loss of pressure in the hydraulic
circuit
1. Check that the motor in the
hydraulic unit turns in the correct
direction
2. Adjust the pressure in the hydrau-
lic circuit
3. Eliminate the pressure loss
The machine (trolley, arm, or chuck)
does not make any hydraulic powe-
red movements
1. The motor in the hydraulic unit is
not turning in the correct direction
2. The thermomagnetic switch is not
on
3. The fuse on the 24V supply is
blown
1. Reverse the phases in the mains
plug
2. Switch on the thermomagnetic
switch
3. Replace the fuse
ALTRI EVENTUALI MALFUNZIONAMENTI SONO DI CARATTERE PREVALENTEMENTE TECNICO E DEVONO ESSERE
CONTROLLATI ED EVENTUALMENTE RIDOTTI DA PERSONALE TECNICO PROFESSIONALMENTE QUALIFICATO.
OTHER POSSIBLE MALFUNCTIONS ARE PRINCIPALLY TECHNICAL IN NATURE AND MUST BE CHECKED AND RE
SOLVED BY PROFESSIONALL QUALIFIED TECHNICIANS.