EasyManua.ls Logo

Manitou MRT-X 2470 Privilege Plus ST3A S1 - Page 249

Manitou MRT-X 2470 Privilege Plus ST3A S1
336 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-91
IT
EN
DE
Malfunction signalled by the
transmitting unit (Pushbutton)
Identify the radio remote control
malfunction according to the light signals
on the
units. If the problem persists after the
suggested solution has been carried out,
contact the support service of MANITOU
Malfunction signalled by the receiving
unit (Pushbutton)
Identify the radio remote control
malfunction according to the light signals
on the
units. If the problem persists after the
suggested solution has been carried out,
contact the support service of MANITOU
Signals Possible reason Solutions
The LED POWER is off. The receiving unit is switched off. Make sure that fuse F2 is intact.
Correctly plug in the connecting plug
and power on the receiving unit.
The POWER LED is on. No radio link. Bring the transmitting unit close to the
receiving unit.
The ALARM LED
blinks once.
Error on the STOP outputs. Make sure that fuses F3 and F4 are
intact.
Correctly plug in the connecting plug.
Make sure that the STOP outputs are
wired correctly.
The ALARM LED
blinks twice.
Error on the SAFETY outputs. Make sure that fuses F1 and F5 are
intact. Correctly plug in the connecting
plug. Make sure that the SAFETY outputs
are wired correctly.
The ALARM LED
blinks three times.
Error on the outputs corresponding to
direction commands.
Contact the support service of the
machine manufacturer.
Make sure that the outputs of direction
commands are wired correctly.
The ALARM LED is on. The receiving unit
does not work correctly.
Contact the support service of the
machine manufacturer.
The RUN LED blinks. The receiving unit does not send
commands in the CAN network.
Contact the support service MANITOU.
The ERR LED blinks. CAN communication error. Contact the support service MANITOU.
Signals Possible reason Solutions
The green LED does not switch on when
the START pushbutton is pressed, even
though both the battery and the S-KEY
are inserted.
The battery is flat. Replace the battery with a charged
one.
The green LED blinks fast. No radio link. Bring the transmitting unit close to the
receiving unit.
The red LED switches on for 2 seconds and
then the unit switches off.
The transmitting unit does not work
correctly.
Contact the support service MANITOU.
The red LED blinks once during start up. The STOP pushbutton is locked or
damaged.
Unlock the STOP pushbutton.
If this signal persists, contact the support
service MANITOU.
The red LED blinks twice during start up. At least one of the actuators corresponding
to commands is activated or damaged.
Bring the actuators to the rest position.
If this signal persists, contact the
support service MANITOU.
The red LED blinks three times during start
up.
The battery is flat. Replace the battery with a charged
one.
The red LED blinks four times during start
up.
At least one of the actuators corresponding
to commands is activated or damaged.
Bring the actuators to the rest position.
If this signal persists, contact the support
service MANITOU.
648970 IT-EN-DE (04/10/2016)