5 - PREHEATING ROD
MT 732 Série C-E2
MT 732 Turbo Série C-E2
MT 932 Série C-E2
MT 932 Turbo Série C-E2
MT 1030 S Série 3-E2
MT 1030 S Turbo Série 3-E2
Enables the motor unit to be kept warm during prolonged periods of stoppage and thus,
ensures the improved start-up of the I.C. engine.
SUPPLY CHARACTERISTICS OF PREHEATING SYSTEM:
• Rated range of power: 220-240V ; 50-60Hz
• Current consumed: 4,5A
• Equipment in class 1
• Equipment connectable only on feeder circuit TT or TN
• Category of insulation 2
ENVIRONMENTAL CONDITIONS IN USE:
• Maximum ambient temperature for using preheating: + 25° C
• Pollution level 2
CONDITIONS FOR CONNECTION AND USE OF PREHEATING:
- The preheating system should not be used for an external ambient temperature higher than + 25° C.
- It is essential that the power supply to the preheating system is:
• Effected with a cable that conforms to the installation standards in force and contains a protective earth conductor.
• Contains an appropriate sectioning system.
• Incorporates an appropriate safety system against short circuits (fuses or circuit breaker) and a differential circuit
breaker with 30mA sensitivity.
- Only connect to and disconnect from the power supply while the unit is off and the I.C. engine is stopped.
6 - DIGICODE ANTI-THEFT SYSTEM
FUNCTIONING
- Switch on the lift truck: LED A flashes red.
- Enter your user code followed by "VAL": LED A goes out.
- The entry of each figure in your code is confirmed by LED A lighting up green. If you make
an error, press the “ANN” key and re-enter your code completely.
- Start the lift truck within the next 30 seconds ; otherwise the anti-theft system will react
and LED A flashes red.
NOTE: You can restart the lift truck within 12 seconds of stopping it: after this time, the
anti-theft system reacts and LED A flashes red.
7 - FINTRONIC ANTI-START SYSTEM
FUNCTIONING
- Switch on the lift truck and set the black key A next to the antenna B (maximum 80 mm).
- Wait a few seconds for red LED C to go out before starting the lift truck.
NOTE: You can restart the lift truck within 20 seconds of stopping it: after this time, the
anti-start system reacts and LED C flashes red.
C
A
B
2 - 37
NO PHOTO