EasyManuals Logo

Manitowoc CVD1475 User Manual

Manitowoc CVD1475
204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #140 background imageLoading...
Page #140 background image
–136–
SAFETY LIMIT INDICATION
Control Board with Black Microprocessor
When a safety limit condition causes the ice machine
to stop, the harvest light on the control board
continually flashes on and off. Use the following
procedures to determine which safety limit has
stopped the ice machine.
1. Move the toggle switch to OFF.
2. Move the toggle switch back to ICE.
3. Watch the harvest light. It will flash one or two
times, corresponding to safety limits 1 and 2, to
indicate which safety limit stopped the ice machine.
After safety limit indication, the ice machine will restart
and run until a safety limit is exceeded again.
Control Board with Orange Label and 302 on
Microprocessor
When a safety limit condition is exceeded for 3
consecutive cycles the control board enters the limit to
memory and the ice machine continues to run. Use the
following procedure to determine if the control board
contains a safety limit indication.
1. Move the toggle switch to OFF.
2. Move the toggle switch back to ICE.
3. Watch the harvest light. It will flash one or two
times, corresponding to safety limits 1 and 2, to
indicate which safety limit stopped the ice machine.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc CVD1475 and is the answer not in the manual?

Manitowoc CVD1475 Specifications

General IconGeneral
BrandManitowoc
ModelCVD1475
CategoryIce Maker
LanguageEnglish

Related product manuals