38 Part Number: 000013325 Rev 01 4/16
Operation Section 3
OPERATIONAL CHECKS
General
Manitowoc ice machines are factory-operated and adjusted
before shipment. Normally, new installations do not require
any adjustment.
To ensure proper operation, always follow the
Operational Checks:
when starting the ice machine for the first time
after a prolonged out of service period
after cleaning and sanitizing
NOTE: Routine adjustments and maintenance procedures
are not covered by the warranty.
MINIMUM/MAXIMUM SLAB WEIGHT
Adjust ice thickness to meet chart specifications.
Model
Minimum
Ice Weight
Per Cycle
lbs
Grams
Maximum
Ice Weight
Per Cycle
lbs
Grams
i300
2.40 lbs
1089 grams
2.80 lbs
1270 grams
i320 - i450 - i520
3.40 lbs
1542 grams
3.90 lbs
1769 grams
i500 - i680 - i686 i690 - i696
4.60 lbs
2087 grams
5.20 lbs
2359 grams
i600 - i606
4.12 lbs
1869 grams
4.75 lbs
2155 grams
i850 - i870 - i890 - i976
5.75 lbs
2608 grams
6.50 lbs
2948 grams
i906 -i1000 - i1006 - i1070
6.2 lbs
2812 grams
7.2 lbs
3266 grams
i1200
7.50 lbs
3402 grams
8.20 lbs
3719 grams
i1090
7.50 lbs
3402 grams
8.50 lbs
3856 grams
i1400 - i1406
10.25 lbs
4649 grams
11.50 lbs
5216 grams
i1470
12.0 lbs
5443 grams
14.0 lbs
6350 grams
i1800
13.20 lbs
5987 grams
14.80 lbs
6713 grams
i1870 - i2170 - i2176
15.5 lbs
7031 grams
16.75 lbs
7598 grams
Ice Thickness Check
After a harvest cycle, inspect the ice cubes in the ice storage
bin. The ice thickness probe is factory-set to maintain the
ice bridge thickness at 1/8" (3 mm).
NOTE: Make sure the water curtain is in place when
performing this check. It prevents water from splashing out
of the water trough.
1. Inspect the bridge connecting the cubes. It should be
about 1/8" (3 mm) thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase bridge
thickness, counterclockwise to decrease bridge
thickness. Set at 9/32" (7 mm) gap between ice
thickness probe and evaporator as starting point, then
adjust to achieve a 1/8" (3 mm) bridge thickness.
NOTE: Turning the adjustment one-third of a turn will
change the ice thickness about 1.5 mm (1/16").
3 mm (1/8")
ICE BRIDGE THICKNESS
PLACE 7 mm (9/32") DRILL BIT
HERE BETWEEN PROBE AND
EVAPORATOR TO SET INITIAL GAP
ADJUSTING SCREW
Ice Thickness Check
Make sure the ice thickness probe wire doesnt restrict