42 Part Number STH025 11/16
Step 4 Wait until the clean cycle is complete
(approximately 24 minutes). Then disconnect power to
the ice machine (and dispenser when used).
n
Warning
Disconnect the electric power to the ice machine at
the electric service switch box.
Step 5 Remove parts for cleaning.
Please refer to the proper parts removal for your ice
machine. Continue with step 6 when the parts have been
removed.
Single Evaporator Ice Machines - page 48
Step 6 Mix a solution of cleaner and lukewarm water.
Depending upon the amount of mineral buildup, a larger
quantity of solution may be required. Use the ratio in the
table below to mix enough solution to thoroughly clean
all parts.
Solution Type Water Mixed With
Cleaner 1 gal. (4 L) 16 oz (500 ml)
cleaner
,
CAUTION
Do not clean the ice thickness probe in a dishwasher.
Permanent damage to the ice thickness probe will
occur.