National Crane Published 12-21-2012 Control # 103-06 6-9
6
1400A OPERATOR’S MANUAL MAINTENANCE CHECKLIST
System is in a state of
constant cut-out.
Blown fuse.
Check fuse at crane cab console. Replace if
necessary.
ATB switch open. Ensure that ATB switch is closed.
System cuts out too early or
too late.
RCL programmed wrong. Reprogram RCL with correct lift values.
Jib Jack Troubleshooting
Will not lift load.
No oil in system.
Release valve not closed.
Add oil to reservoir.
Turn handle clockwise tightly.
Will lift load only part way. Oil level low. Add oil to reservoir tank.
Will lift load but will not
hold.
The following valve or valves leaking.
a. Suction valve
b. Delivery valve
c. Release valve
Replace jack
Packings worn or damaged. Replace jack
Jack will not lower.
Release valve stuck, probably dirt or
foreign matter.
Transfer load then replace dirty oil, flush oil
reservoir with non-flammable solvent.
Poor lifting.
Dirty oil.
Air in hydraulic system.
Change oil.
Purge air from system.
Poor pumping action.
Oil seal for pump unit worn in out or
damaged.
Replace jack.
Condition Possible Cause Possible Solution
Reference Only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc National Crane 1400A and is the answer not in the manual?

Manitowoc National Crane 1400A Specifications

General IconGeneral
BrandManitowoc
ModelNational Crane 1400A
CategoryConstruction Equipment
LanguageEnglish

Related product manuals