EasyManuals Logo
Home>Manitowoc>Ice Maker>NEO UD0140W

Manitowoc NEO UD0140W Technician's Handbook

Manitowoc NEO UD0140W
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #86 background imageLoading...
Page #86 background image
86 Part Number STH042 7/15
Use the following procedure and table to help determine
if a harvest valve is remaining partially open during the
freeze cycle.
1. Wait five minutes into the freeze cycle.
2. Feel the inlet of the harvest valve(s).
Important
Feeling the harvest valve outlet or across the harvest
valve itself will not work for this comparison.
The harvest valve outlet is on the suction side (cool
refrigerant). It may be cool enough to touch even if
the valve is leaking.
3. Feel the compressor discharge line.
Warning
The inlet of the harvest valve and the compressor
discharge line could be hot enough to burn your
hand. Just touch them momentarily.
4. Compare the temperature of the inlet of the harvest
valves to the temperature of the compressor
discharge line.

Table of Contents

Other manuals for Manitowoc NEO UD0140W

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc NEO UD0140W and is the answer not in the manual?

Manitowoc NEO UD0140W Specifications

General IconGeneral
BrandManitowoc
ModelNEO UD0140W
CategoryIce Maker
LanguageEnglish

Related product manuals