Water Assist Harvest Cycle
The maximum harvest time is a total of 7 minutes.
If the bin switch does not activate within 7 minutes a
water assist harvest cycle initiates using the following
sequence:
1. The compressor de-energizes.
2. The water inlet valve energizes and fills the water
trough.
3. The water pump energizes for 2 minutes and
circulates water over the evaporator.
If the bin switch did not open & close.
4. The water dump valve energizes and drains water
from the water trough.
5. Step 1 through 4 repeat.
6. A freeze cycle starts.
NOTE: If the bin switch opens & closes anytime during the
cycle the ice machine starts a new freeze cycle.
The maximum water fill time for the water assist
harvest is 105 seconds.