Part Number 80-1505-3 6/11 155
The ice thickness probe must be set to maintain the
ice bridge thickness at approximately 1/8 in. If ice
forms uniformly across the evaporator surface, but
does not reach 1/8 in. in the proper amount of time,
this is still considered normal ice fill pattern.
2. Extremely Thin at Evaporator Outlet
There is no ice, or a considerable lack of ice formation,
at the evaporator outlet.
Examples: No ice at all at the outlet half of the
evaporator, but ice forms on the inlet half of the
evaporator. Or, the ice at the outlet of the evaporator
reaches 1/8 in. to initiate a harvest, but the inlet of the
evaporator already has 1/2 in. to 1 in. of ice formation.
3. Extremely Thin at Evaporator Inlet
There is no ice, or a considerable lack of ice formation
on the evaporator inlet. Examples: The ice at the outlet
of the evaporator reaches 1/8 in. to initiate a harvest,
but there is no ice formation at all on the inlet of the
evaporator.
4. No Ice Formation
The ice machine operates for an extended period, but
there is no ice formation at all on the evaporator.