Do you have a question about the Manitowoc QR0670C and is the answer not in the manual?
Model | QR0670C |
---|---|
Ice Production Capacity | 670 lbs per day |
Ice Type | Dice or Half Dice |
Weight | 200 lbs |
Daily Ice Production | 670 lbs |
Ice Production | 670 lbs per day |
Refrigerant | R404A |
Electrical Requirements | 115/60/1 |
Condenser Type | Air-Cooled |
Width | 30" |
Ice Storage | Requires separate storage bin |
Ice Shape | Cube |
Voltage | 115/60/1, 208-230/60/1, or 208-230/60/3 |
General guidance on paying attention to safety notices in the handbook for injury prevention.
Helpful information and tips to assist technicians during equipment procedures.
Lists the ice machine head sections and corresponding CVD condensing units covered by the manual.
Details warranty coverage, including registration and exclusions for the ice machines.
Criteria for selecting locations and necessary clearances for ice machines and condensing units.
Details the electrical specifications and wiring requirements for QuietQube ice machines and CVD condensing units.
Guidelines for installing the refrigeration system, including line set selection and sizing.
Procedures to perform for ensuring proper operation when starting the ice machine for the first time or after service.
Detailed explanation of the ice making process cycles for different models and their components.
Method for verifying the ice production rate of the machine under various operating conditions.
Procedures for cleaning and sanitizing the ice machine interior surfaces using approved solutions.
Instructions on how to remove specific parts like water trough, valves, and probes for thorough cleaning.
Information about the automatic cleaning system accessory for scheduled maintenance.
Information on control board components, fuses, switches, and safety limit indicators for troubleshooting.
Steps to troubleshoot issues with ice machine head sections or condensing units not running or producing ice.
Analysis of refrigerant flow, pressures, and component functions during freeze and harvest cycles for diagnosing problems.
Tables to help diagnose refrigeration system malfunctions based on operational analysis and component behavior.
Procedures for safely recovering and evacuating refrigerant from the system using specialized equipment.
Guidelines for cleaning the refrigeration system after contamination or compressor burnout to restore reliability.
Information on liquid line filter-driers, including part numbers and replacement recommendations for system maintenance.