EasyManua.ls Logo

MarelliMotori MARK X - Technical Specifications

MarelliMotori MARK X
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
4. TECHNICAL SPECIFICATIONS
The M40FA644A voltage regulator can be calibrated using potentiometers. The circuit board is resin-bonded in order to
maintain a high degree of operational reliability even in difficult environmental conditions (high levels of humidity, dust, a salty
atmosphere) and in the presence of vibrations.
4.1. Specifications
Power supply voltage (auxiliary windings, main terminals)
±10% of range tolerance, 100/120Hz
170 ÷ 277 Vac
Voltage build-up
5 Vac
Voltage sensing (single-phase)
±10% of range tolerance, 50/60Hz
170 ÷ 480 Vac
Current sensing
0 ÷ 1 Aac
Maximum continuative field current
0 ÷ 8 Adc
Maximum forcing field current (1 minute)
0 ÷ 15 Adc
Maximum field voltage
100 Vdc
Field resistance
3 ÷ 20
Regulation accuracy from no load to full load
From 0 to 100% of the rated load - PF 0.8 - balanced and non deforming load, constant frequency
±0.5 %
Steady state accuracy
@ frequenza e carico costanti
±0.1 %
Accuracy with ±4% engine governing
@ steady state conditions for load and speed
±1 %
Thermal Drift
% voltage change for 50°C change from T
amb
, after 10 minutes
±0.5 %
Response time
1 ciclo
Operating temperature
-30°C ÷ +70°C
Storage temperature
-40°C ÷ +80°C
4.2. Functions
Protection
Under-frequency limiter
Over-excitation limiter
Internal fuse, replaceable
Control
With external potentiometer, 100 kΩ for ∆V = ±5 % of the rated voltage
With external DC voltage signal (-3/+3 V)
Suitable for connection to power factor regulator PFR M50FA400A
Parallel
Reactive droop compensation, ±20 %
4.3. Dimensions
L
180mm
B
170mm
K
160mm
J
150mm
H
41mm
D
6.5mm
Weight
670g
L
B
H
K
J
D