EasyManua.ls Logo

Maritime Geothermal TF-45 User Manual

Default Icon
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1-Jul-2017 Page 1 001223MAN-05
Maritime Geothermal Ltd.
P.O. Box 2555, 170 Plantation Road
Petitcodiac, NB E4Z 6H4
(506) 756-8135
TF-Series
Triple Function Geothermal Heat Pump
Two-Stage R410a
Model Sizes 45-80
info@nordicghp.com
www.nordicghp.com
001223MAN-05
ECO 000250
1-Jul-2017
Installation and Service Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Maritime Geothermal TF-45 and is the answer not in the manual?

Maritime Geothermal TF-45 Specifications

General IconGeneral
BrandMaritime Geothermal
ModelTF-45
CategoryHeat Pump
LanguageEnglish

Summary

Installation and Service Manual

TF-Series Triple Function Geothermal Heat Pump

Overview of the TF-Series unit, its capabilities, and model series.

Safety Precautions

Model Nomenclature

Application Table

Installation Basics

Electrical Connections

Information on power supply, wiring, and electrical box connections for the heat pump.

Thermostat Requirements

Specifies the type of thermostat required for two-stage operation and wiring details.

Aquastat Requirements

Details the requirements for a two-stage aquastat for hydronic heating control and its connections.

Operational Description

Priority Selection

Explains how to set air or hydronic priority for the unit's operation.

Air Return Orientation

Fan/Blower Outlet Orientation

Explains how to field configure the blower outlet for top or side discharge.

Safety Controls

Domestic Hot Water (Desuperheater) Connections

Details port connections and piping for integrating the desuperheater with a pre-heat tank.

Sample Bill of Materials - Ground Loop Installations

Sample Bill of Materials - Open Loop Installations

Lists materials needed for a typical open loop (groundwater) installation.

Typical Thermostat Connections

Two-Stage Models (Compressor Stages = T)

Wiring diagram and connection details for two-stage thermostats.

Modular Parallel TF(H)-Series Aquastat Connection Diagram

Mode Priority

Explains the priority sequence between air and hydronic modes for TF(H) series units.

Typical Heating Only Zone Wiring (TF&DXTF-Series)

In Floor Heating Only ZONE 1

Wiring diagram for a single zone of in-floor hydronic heating.

Water-to-Air Heat Pumps: Wiring for Best Cooling Mode Dehumidification in Heating-Dominant Climates

Single Unit Connection to Domestic Hot Water Pre-Heat Tank (Brass FPT)

Top Port Configuration

Piping diagram for connecting a single unit to a pre-heat tank using top port configuration.

Sizing and Ductwork

Heat Pump Sizing

Guidelines for sizing heat pumps based on home area for different loop systems.

Duct Systems - Grill Layout

Plenum Heater (Optional)

Information on the function and installation of an optional plenum heater for auxiliary heat.

Internal Plenum Heater Installation

Typical Duct & Condensate Connections - TF Series

Duct Sizing Guide

Hydronic Installation

Hydronic Systems

Overview of common hydronic applications for TF-Series heat pumps, including zone systems.

Typical Loop Connections - TF Series

Typical Buffer Tank Configuration - Four Port Tank

Typical Buffer Tank Configuration - Two Port Tank

Typical Zone Types for Hydronic Applications

Single Unit Connection to On-Demand Domestic Hot Water Pre-Heat Tank

Dedicated On-Demand System (No other zones)

Piping diagram for a dedicated on-demand DHW system without other zones.

Ground Loop Installations

Circulator Pump Module

Information on selecting and installing circulator pump modules for ground loop systems.

Adding Antifreeze Solution

Initial Pressurization

Procedures for pressurizing the ground loop system to the correct static pressure.

Typical Horizontal Ground Loop Configuration

Typical Vertical Ground Loop Configuration

Geo-Flo Circulator Pump Module Installation (Units with Brass FPT Fittings)

Dual Flow Circulator Pump Module Installation for 2-Stage Heat Pumps

Geo-Flo Circulator Pump Module Installation - Two Units On One Ground Loop

Open Loop Installations

Well Water Temperature

Information on verifying well water temperature as a critical step for open loop systems.

Well Water Flow

Requirements for well water flow rate and testing procedures for open loop installations.

Water Valve

Water Flow Control

Recommendation for using a flow restricting valve to maintain system backpressure.

Plumbing the Heat Pump

Pipe Insulation

Recommendations for insulating ground water piping to prevent condensation.

Typical Ground Water Installation for Size 25-80 Heat Pumps

Dual Flow Groundwater (Well) Installation

Dual Flow Groundwater (Well) Installation with Slow Closing Water Valve

Installation details for dual-flow systems using slow-closing water valves for water hammer prevention.

GROUND WATER DISPOSAL METHODS

Startup Procedure

Pre-Start Inspection

Checklist for verifying completion of installation steps before powering up the unit.

Unit Startup (Air)

Startup Record (Air)

Unit Startup (Hydronic)

Startup Record Sheet (Hydronic)

General Maintenance

GENERAL MAINTENANCE SCHEDULE

A schedule outlining routine maintenance tasks, intervals, and procedures for the heat pump.

Troubleshooting Guide

POWER SUPPLY TROUBLESHOOTING

Diagnosing and resolving issues related to power supply and thermostat display.

THERMOSTAT TROUBLESHOOTING

FAULT CODE TROUBLESHOOTING

Interpreting and resolving fault codes related to pressure controls, overflow, and brownout.

COMPRESSOR TROUBLESHOOTING

OPERATION TROUBLESHOOTING - AIR HEATING MODE

High Discharge Pressure

Troubleshooting steps for high discharge pressure issues in air heating mode.

OPERATION TROUBLESHOOTING - AIR COOLING MODE

Heating instead of cooling

Diagnosing and resolving issues where the unit heats when cooling is called for.

OPERATION TROUBLESHOOTING - COOLING MODE

High Discharge Pressure

Troubleshooting steps for high discharge pressure issues in cooling mode.

FAN/BLOWER TROUBLESHOOTING

HYDRONIC TROUBLESHOOTING - AQUASTAT

HYDRONIC OPERATION TROUBLESHOOTING

High Discharge Pressure

Troubleshooting steps for high discharge pressure in hydronic heating mode.

PLENUM HEATER TROUBLESHOOTING

DOMESTIC HOT WATER (DESUPERHEATER) TROUBLESHOOTING

Repair Procedures

PUMP DOWN PROCEDURE

Steps for safely recovering refrigerant from the system before performing repairs.

VACUUM AND CHARGING PROCEDURE

Procedures for vacuuming and charging the refrigeration circuit with refrigerant after repairs.

Model Specific Information

Standard Capacity Ratings

Tables detailing standard capacity ratings for ground loop and ground water heating and cooling.

Pressure Drop Data

Performance Tables (Air)

Air Heating Mode

Performance data for the TF-45 unit in air heating mode across various operating conditions.

Air Cooling Mode

Performance data for the TF-55 unit in air cooling mode across various operating conditions.

Performance Tables (Air)

Air Heating Mode

Performance data for the TF-65 unit in air heating mode across various operating conditions.

Air Cooling Mode

Performance data for the TF-65 unit in air cooling mode across various operating conditions.

Performance Tables (Air)

Air Heating Mode

Performance data for the TF-75 unit in air heating mode across various operating conditions.

Air Cooling Mode

Performance data for the TF-75 unit in air cooling mode across various operating conditions.

Performance Tables (Hydronic)

Hydronic Heating Mode

Performance data for the TF-45 unit in hydronic heating mode across various operating conditions.

Performance Tables (Hydronic)

Hydronic Heating Mode

Performance data for the TF-55 unit in hydronic heating mode across various operating conditions.

Performance Tables (Hydronic)

Hydronic Heating Mode

Performance data for the TF-75 unit in hydronic heating mode across various operating conditions.

Airflow Data

Table 27: MED Airflow (nominal)

Airflow specifications for medium airflow settings across different unit sizes and modes.

Table 28: LOW Airflow (-6%)

Airflow specifications for low airflow settings across different unit sizes and modes.

Table 29: HIGH Airflow (+6%)

Airflow specifications for high airflow settings across different unit sizes and modes.

Electrical Tables

Table 31 - Heat Pump Electrical Information (208/230-1-60)

Electrical specifications for heat pumps operating on 208/230V, 1-phase, 60Hz power.

Electrical Tables (continued)

TABLE 36 - Plenum Heater Electrical Information

Electrical specifications for plenum heaters across different voltage and wattage ratings.

Wiring Diagram (208/230-1-60)

Electrical Box Layout (208/230-1-60)

Wiring Diagram (208-3-60)

Electrical Box Layout (208-3-60)

Wiring Diagram (460-3-60)

Electrical Box Layout (460-3-60)

Wiring Diagram (220-1-50)

Electrical Box Layout (220-1-50)

TF Refrigeration Circuit - Air Heating Mode

TF Refrigeration Circuit - Air Cooling Mode

TF Refrigeration Circuit - Hydronic Heating Mode

Dimensions: TF-45 Left Return

Dimensions: TF-45 Right Return

Dimensions: TF-55/65/75/80 Left Return

Dimensions: TF-55/65/75/80 Right Return

LIMITED EXPRESS WARRANTY

LIMITED EXPRESS RESIDENTIAL WARRANTY - PARTS

Details the warranty coverage for parts of MG residential class products.

LIMITED EXPRESS RESIDENTIAL WARRANTY - LABOUR

Outlines the labor coverage provided under the residential warranty for authorized service personnel.

Related product manuals