E L E C T R I C S T E R I L M A T I C S T E R I L I Z E R
OWNER’S MANUAL
E L E C T R I C S T E R I L M A T I C S T E R I L I Z E R
DIGITAL VERSION
03/14 REV. A
H-2117
INSTALLATION
OPERATION
MAINTENANCE
TROUBLE-SHOOTING
PARTS & SERVICE
WARRANTY
DOMESTIC MODEL: STM-ED
EXPORT MODEL:
STM-EDX
35 Garvey Street, Everett, MA 02149
Telephone: (617) 387-4100, (866) 698-3188
Fax: (617) 387-4456, (800) 227-2659
custserv@m i.com, www.m i.com
FORM NO.:
Sterilizers.com - Your Sterilizer Expert
Distribution Maintenance - Guaranteed
Alfa Medical - 10 Bond St Great Neck NY 11021
1-800-762-1586 - info@Sterilizers.com

Table of Contents

Questions and Answers

  • K
    Kenneth MarquezAug 4, 2025
    What to do if my Market Forge Industries Steriliser operates, but doesn't build up 15.5 PSI pressure?
    • S
      Sierra HowardAug 5, 2025
      If your Market Forge Industries Steriliser isn't reaching the correct pressure, here are a few things to check: * First, see if all the heating elements are working by removing the lower front panel and observing them. * Second, the exhaust valve may not be holding pressure; consider replacing it. * Third, check for steam leaks around the door, which might indicate a worn gasket or the need for door adjustment. * Finally, the safety valve might be blowing off too early, in which case it should be replaced.
  • M
    martinezgeorgeAug 10, 2025
    Why Market Forge Industries Steriliser fails to operate at all?
    • M
      Monica CervantesAug 10, 2025
      If your Market Forge Industries Steriliser isn't operating, consider the following potential causes: 1. Incorrect installation: Verify the wiring using the wire diagram. 2. Blown fuse: Replace the fuse, and ensure the electrical supply is 60 amps. 3. Burned out contactor: Replace the contactor. 4. Defective wiring: Inspect all wiring, and repair or replace as necessary.
  • A
    Amy SmithAug 19, 2025
    What to do if Market Forge Industries Steriliser releases pressure prematurely?
    • N
      Natalie MosleyAug 19, 2025
      If your Market Forge Industries Steriliser is releasing pressure before the cycle is complete, it may be due to the low water cut-off malfunctioning. Try replacing the low water cut-off.
  • J
    Jill PorterAug 27, 2025
    How to fix Market Forge Industries Steriliser heating element staying on during the cycle?
    • C
      Christian ThomasAug 27, 2025
      If the heating elements in your Market Forge Industries Steriliser remain on during the timing/sterilization cycle, the contactors of the temperature control switch might be stuck closed. Replacing the switches may resolve this issue.

Summary

Section 1 Installation Instructions

Installation

General guidance for physically setting up the sterilizer unit.

Electrical

Requirements and connection procedures for electrical power supply.

Electrical Requirements

Outlines electrical power specifications and voltage requirements.

Electric Supply Connections for STM-ED

Specific instructions for connecting the electrical supply to the STM-ED model.

Electric Supply Connections for STM-EDX

Specific instructions for connecting the electrical supply to the STM-EDX model.

1 Phase Wiring Diagram

Schematic diagram for single-phase electrical connections.

3 Phase Wiring Diagram

Schematic diagram for three-phase electrical connections.

Typical Circuit Connection for STM-ED Sterilizer

Illustrates typical circuit connections for the STM-ED model under various voltage conditions.

Section 2 Water Conditions

Section 3 Operating Instructions

Load Sterilizer

Procedures for correctly loading items into the sterilizer chamber.

Determine Correct Sterilization Times

Guidance on setting appropriate sterilization times based on load type.

Sterilization Guide

Recommendations for arranging various articles for effective sterilization.

Minimum Sterilization Times

Table detailing minimum sterilization times for different types of articles.

Manual Programming

How to manually program temperature, time, and vent settings.

Setting Temperature

Steps to set the desired sterilization temperature set-point.

Setting Time

Steps to set the desired sterilization time.

Programming PRESET Keys

Detailed steps for saving custom sterilization parameters to preset keys.

Low Water Reset

What occurs during a low water condition and how to reset it.

Steps to Reset the Unit

Specific steps to follow to reset the unit after an error.

Section 4 Maintenance

Daily Cleaning Procedure

Essential steps for daily cleaning of the sterilizer chamber.

Section 5 Field Service Instructions & Assembly

Door Adjustment

Procedure for adjusting the door seal for a proper steam-tight fit.

The Low Water Cut-Off (Manual Reset)

Explanation of the low water cut-off safety feature and manual reset.

The Safety Valve

Description and function of the safety valve for pressure relief.

Section 7 Trouble-Shooting

Trouble Shooting Guide

Guide to diagnose and correct common operational problems.

Section 8 Appendix

Error Codes

List and explanation of error codes displayed by the unit.

Market Forge Industries STM-ED Specifications

General IconGeneral
BrandMarket Forge Industries
ModelSTM-ED
CategorySteriliser
LanguageEnglish