“MGTE” Series
1 1/2” Metered & Time Clock
COMMERCIAL WATER CONDITIONERS
INSTALLATION, OPERATION,
AND MAINTENANCE MANUAL
MODEL NO:
SERIAL NO:
DATE INSTALLED:
DEALER:
COMPLETE FOR FUTURE REFERENCE:
Marlo Incorporated
2227 South Street
P.O. Box 044170
Racine, WI 53404-7003
Ph. (262) 681-1300
Fax (262) 681-1318
Info@Marlo-Inc.com
www.Marlo-Inc.com
8-193 R1

Questions and Answers

  • M
    Michelle BradleyAug 12, 2025
    What to do if the time of day flashes on and off on my Marlo Incorporated MGTE Clock?
    • M
      mcdonaldchristopherAug 12, 2025
      If the time of day display is flashing, it likely means there was a power outage lasting more than two hours, the transformer was unplugged and plugged back in, or the NEXT and REGEN buttons were pressed, resetting the valve. To resolve this, simply reset the time of day.
  • D
    Dr. Amanda Nguyen MDAug 16, 2025
    Why does my Marlo Incorporated MGTE control valve regenerate at the wrong time of day?
    • G
      Glen LopezAug 16, 2025
      The control valve might be regenerating at the wrong time of day due to several reasons: * Power outages may have occurred. * The time of day may not be set correctly. * The regeneration time is incorrect. * The control valve is set at 'on 0' (immediate regeneration). * The control valve is set at NORMAL + on 0. To fix this, reset the control valve to the correct time of day, ensuring the a.m./p.m. setting is accurate. Also, reset the regeneration time, and check the control valve set-up procedure, especially the regeneration time option.
  • E
    Evan HowardAug 20, 2025
    What to do if my Marlo Incorporated Clock control valve does not regenerate automatically but does when REGEN button is depressed?
    • J
      jessica01Aug 20, 2025
      If your control valve only regenerates when the REGEN button is pressed, but not automatically, it could be due to: * A by-pass valve being in the bypass position. * A disconnected meter connection. * A restricted or stalled meter turbine. * A defective meter. * A defective PC board. * A set-up error. To solve this, put the control valve in the service position, connect the meter to the PC board, remove the meter and check for rotation or foreign material, replace the meter if defective, replace the PC board if defective, and check the control valve set-up procedure to correct any errors.
  • M
    Michael RobinsonAug 23, 2025
    What to do if my Marlo Incorporated MGTE Clock timer does not display the correct time of day?
    • B
      Brandon BennettAug 23, 2025
      If the timer is showing the wrong time, it might be because: * The outlet is switched. * There was a power outage. * The PC board is defective. To fix this, use an uninterrupted outlet, reset the time of day after a power outage, or replace the PC board if it's defective.
  • I
    isabelfarrellAug 27, 2025
    How to fix a Marlo Incorporated Clock control valve that is stalled in regeneration?
    • C
      Catherine HawkinsAug 27, 2025
      If the control valve is stuck during regeneration, the possible causes are: * The motor is not operating. * There is no electric power at the outlet. * The transformer is defective. * The PC board is defective. * The drive gear or drive cap assembly is broken. * The piston retainer is broken. * The main or regenerant piston is broken. To resolve this, replace the motor, repair the outlet or use a working one, replace the transformer, replace the PC board, replace the drive gear or drive cap assembly, replace the drive cap assembly, or replace the main or regenerant piston.
  • C
    Christine WilliamsAug 31, 2025
    What to do if my Marlo Incorporated MGTE timer does not display time of day?
    • N
      Nicole PalmerAug 31, 2025
      If the timer isn't showing the time, check these possible causes: * The transformer might be unplugged. * There might be no power at the outlet. * The transformer could be defective. * The PC board might be defective. To solve this, connect the power, repair the outlet or use a working one, replace the transformer, or replace the PC board.
  • C
    Catherine CastanedaSep 3, 2025
    What to do if my Marlo Incorporated MGTE control valve does not regenerate automatically when REGEN button is depressed and held?
    • B
      Bryan GallagherSep 4, 2025
      If the control valve fails to regenerate automatically when the REGEN button is depressed and held, check for these issues: * The transformer is unplugged. * There is no electric power at the outlet. * The drive gear or drive cap assembly is broken. * The PC board is defective. To fix this, connect the transformer, repair the outlet or use a working one, replace the drive gear or drive cap assembly, or replace the PC board.
  • D
    Danielle SimmonsSep 7, 2025
    What to do if there is no softening/filtering display when water is flowing in my Marlo Incorporated MGTE Clock?
    • J
      Jimmy JohnsonSep 7, 2025
      If there's no softening/filtering display while water is flowing, it could be due to: * The bypass valve being in the bypass position. * The meter connection being disconnected. * A restricted or stalled meter turbine. * A defective meter. * A defective PC board. To resolve this, put the bypass valve in the service position, connect the meter to the PC board, remove the meter and check for rotation or foreign material, replace the meter, or replace the PC board.

Summary

Specification Chart

Installation Instructions

Loading Softener Tank Media

Detailed steps for loading gravel and resin into the softener tank, including important precautions.

Mounting Control Valve Assembly

Instructions for securely mounting the control valve onto the softener tank, ensuring a proper seal.

Connecting Fittings and Drain Lines

Guidelines for connecting all fittings, including drain and overflow lines, with essential safety notes.

Pressure Testing the Installation

Steps to pressure test the installed plumbing system for leaks and proper operation before full use.

Control Valve Function and Cycles

Details the operation and cycle sequences of the automatic control valve for water softeners and filters.

Operation and Settings

Installer Display Settings Overview

Guides the installer through setting critical parameters like water hardness, regeneration intervals, and regeneration times.

Key Installer Configuration Parameters

Details specific settings for water hardness, regeneration days, and regeneration time (hour and minutes).

Maintenance and Parts

Meter Assembly Service and Installation

Instructions for servicing and installing 1-1/2" and 2" meter assemblies, including turbine replacement.

Troubleshooting Guide

Troubleshooting Guide (Continued)

Continues the troubleshooting guide, covering additional problems and solutions for the control valve and timer.