OPERATION AND SERVICE MANUAL
UTL-200
Portable Ullage Temperature Interface Detector
(Gas-Tight)
NOTE
- Before using the instrument please read this manual
- Determines Ullage, Temperature, Interface
- Detection of Ultra Sensing Probe
- Measuring Tape : 15 / 30 / 37 m
- Easy Installation & Operation
- Easy Maintenance

Questions and Answers

Summary

Before Use

Manual Overview and Safety Guidelines

Explains manual's purpose, emphasizes reading contents, and highlights professional work in safety areas and periodic calibration.

Product Description

Product Overview and Compliance

Explains the product's purpose, advantages over fixed systems, and compliance with MARPOL regulations.

Key Features of UTL-200

Highlights immediate measurement, ultrasonic detection, intrinsic safety, portability, and adherence to MARPOL standards.

Product Identification and Signals

Details serial number usage, beep signals for different substances, and battery status indication.

Product Specifications

Technical Specifications

Lists accuracy, tape length, resolution, probe diameter, temperature ranges, display, power source, and ex-grade.

Measuring Principle

Sensing Probe Technology

Describes the combined ultrasonic, temperature, and conductive sensors within the sensing probe.

Ullage Detection Mechanism

Explains the ultrasonic sensor's method of detecting oil/water interfaces via acoustic impedance and beep alerts.

Interface Detection Mechanism

Details how water conductivity activates continuous beeps using interface sensor electrodes.

Temperature Measurement Principle

Explains the proportional signal output for absolute temperature and the reference for calibration.

Measuring Tape Construction

Describes the tape's composition: steel tape, steel core (2 wires), and Teflon coating.

Operation

UTL-200 Component Layout

Illustrates the device's components including mechanical body, electronic box, and sensing unit.

Deck Valve Specifications

Provides a list of valve sizes and flange connections for UTL-DV2 models.

Panel Button and Display Functions

Explains the operation of LCD display, POWER, NEXT, ENTER, BACK buttons, buzzer, and LED indicators.

Internal Setting: Temperature Correction

Details the procedure for adjusting the temperature correction value using the device's buttons.

Internal Setting: Temperature Unit

Describes how to select the desired temperature unit (°C or °F) via the device's menu.

Internal Setting: Battery Check

Outlines the steps to verify the remaining battery power on the UTL-200 unit.

Internal Setting: LED and Backlight Control

Explains toggling between beep/LED modes and activating/deactivating the LCD backlight.

Ullage and Interface Measurement Procedure

Provides step-by-step instructions for installing, operating, and performing ullage/interface measurements.

Reading Index Adjustment Procedure

Details how to confirm and adjust the reading index if measurement errors are detected.

Temperature Measurement Procedure

Guides on performing temperature measurements, including achieving stable readings and confirmation.

Installation and Ullage Reading

Installation Dimensions and Requirements

Specifies installation dimensions (H1, H2) and valve connection requirements for the device.

Care and Maintenance

General Care and Cleaning

Provides guidance on cleaning the product, storing the sensor probe, and maintaining its dry storage.

Battery Check Procedure

Explains how to check the battery status of the UTL-200 through its operational menu.

Battery Replacement Procedure

Details the steps for safely replacing the battery in a designated safe area.

Sensing Probe Replacement

Covers the process of separating the old probe and connecting a new sensing probe.

Display Unit Replacement Procedure

Explains how to replace the display unit if the LCD or PCB malfunctions.

Tape Wipers Replacement

Details the procedure for replacing tape wipers when they no longer clean effectively due to dust.

Tape Replacement Procedure

Provides a step-by-step guide for replacing the measuring tape, including disassembly and reassembly steps.

Insulation Test Procedure

Guides on how to perform an insulation test on the device's components for proper functioning.

Reel Tape Condition Check

Explains how to check the reel tape's condition by examining connector resistance.

Troubleshooting Guide

Power Supply and Measurement Issues

Lists problems with power, battery, buzzer, and beep sounds, along with their causes and solutions.

Temperature and Communication Issues

Addresses temperature reading errors, contaminated sensors, and communication problems like 'Sensor Check'.

Spare Parts

List of Spare Parts

Lists spare parts such as batteries, wrenches, drivers, O-rings, and bolts with their specifications.

Warranty Information

Warranty Claim Procedure

Outlines the procedure for reporting defects and the information required for warranty claims.

Warranty Disclaimer and Limitations

Covers conditions for warranty invalidation, limitations, and exclusions for damages.

Carriage Charges for Warranty

States that freight costs for warranty service are the responsibility of the purchaser.

Certificates

Type Approval and Quality System Certificates

Lists EC Type Examination, EC Quality System Assessment, and other relevant type approval certificates.

Marsen UTL-200 Specifications

General IconGeneral
BrandMarsen
ModelUTL-200
CategorySecurity Sensors
LanguageEnglish