EasyManua.ls Logo

MARSHELL DG24800 - Fault Phenomena 2; Fault Phenomena 3

MARSHELL DG24800
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
cause of the fault components are: battery connecting wire loose, overload protection device for large current and
protection (disconnect) and electronic lock connection wire loose or damage etc.
Maintenance procedures:
First, check the current recovery insurance, and press the white plastic cover on the reinstatement of the
insurance, if pop-up indicates that the insurance has returned to function. If failure is not eliminated then go on
next step;
Close the key and then open it once, feels the lock switch is normal and no shaking loose feeling, or it will need to
replace the locks. If normally, then go on next step;
Take apart the seat and the rear body, carefully checking if it’s the battery connecting wire not firm and
connector is not good contacts. Check the voltage of the charger socket 1 and 2 .Normally is 24V, or it is the
connection wires problem.
Fault phenomena 2:
Open the electronic key power indicator indicates light, when speed up the cart it doesn't walk.
Cause analysis: Power shows light that shows the circuit is normal, that is usually the clutch handle position of the
handle is wrong.
Elimination method: put the clutch handle at the correct position (direction down).
Fault phenomena 3:
Open headlight switch, headlamps do not bright but back one light.
Cause analysis: tail lights and headlamps switched by headlight, tail light but headlamps do not bright only have
two reasons:
1, The headlamps bulbs burn out, so replacement bulbs are needed.
2, Headlamps connections and headlamps lead wire are loose, then contact undesirable parts.