Do you have a question about the Martec MBHL1000W and is the answer not in the manual?
Cut a 125mm diameter hole on the wall for the vent position.
Connect and seal the 120mm duct to the vent hole and exterior.
Position the heater no more than 2.3m from the ground for best heating results.
Mark and cut the ceiling opening using the template, ensuring clearance.
Remove the fascia by detaching silicon clips and hidden screws.
Carefully remove lamps, avoiding touching halogen lamp with bare skin.
Fit the duct to the fan outlet, install backdraft stopper, and position housing securely.
Install heat lamp, LED lamps, check glass shield, and reattach fascia.
Mount the switch panel and ensure wiring is neat and safe.
Avoid installing above showers/sockets and ensure installation is in flat ceilings only.
Position for heat effectiveness and ensure adequate replacement air for the exhaust fan.
Verify ceiling space for obstructions, clearance, and electrical wiring routing.
Operate the 'HEAT' switch for the halogen heating lamp.
Use the 'FAN' switch to exhaust odours and steam efficiently.
Control the integrated light using the 'Light' switch.
Clean glass shield and fascia with a soft cloth and neutral detergent after powering off.
Replace heat and LED lamps only with specified Martec models, ensuring power is off.
Unit warranted for 3 years; claims void without safety certificate and proper installation.