OPERATION MANUAL
PLATE COMPACTOR
MS50 / MS60 / MS90 / MS100
WARNING
!
To reduce the risk of injury, all operators and maintenance personnel must read and understand these
instructions before operating, changing accessories, or performing maintenance on Masalta power
equipment. All possible situations cannot be covered in these instructions. Care must be exercised
by everyone using, Maintaining or working near this equipment.
R
MS50-2
MS60-2
MS90-4
MS100-4

Questions and Answers

  • L
    Laura JonesAug 14, 2025
    Why is the Masalta MS60-2 travel speed too low and vibration weak?
    • R
      Robert FlemingAug 14, 2025
      Why is the Masalta Construction Equipment travel speed too low and the vibration weak? This could be due to several reasons: * The engine speed might be too low. In that case, set the engine speed to the correct RPM. * The clutch could be slipping. If so, check or replace the clutch. * The V-belt might be slipping. Adjust or replace the V-belt. * There may be excessive oil in the vibration mechanism. Drain the excess oil and fill to the proper level. * There may be a malfunction in the vibrator housing. Check the eccentric, gears, and counter weights. * Bearing failure can also be the cause. Replace the bearing. * Insufficient engine output. Check the engine and compression.
  • R
    Raymond WolfAug 17, 2025
    What to do if Masalta Construction Equipment is hard to start but there is no spark?
    • C
      Cheryl BrownAug 18, 2025
      What to do if my Masalta Construction Equipment is difficult to start, even though fuel is available, but there's no spark at the spark plug? This could be due to: * Spark plug bridging. Check the gap, insulation, or replace the spark plug. * Carbon deposit on the spark plug. Clean or replace the spark plug. * Short circuit due to deficient spark plug insulation. Check the spark plug insulation and replace it if worn. * Improper spark plug gap. Set it to the proper gap.
  • J
    John SmithAug 21, 2025
    What to do if Masalta Construction Equipment is hard to start but compression is low?
    • K
      katherine86Aug 21, 2025
      What should I do if my Masalta Construction Equipment is difficult to start, even though fuel is available, a spark is present, and compression is low? The possible causes are: * Suction/exhaust valve stuck or protruded. Re-seat the valves. * Piston ring and/or cylinder worn. Replace the piston rings and/or piston. * Cylinder head and/or spark plug not tightened properly. Torque the cylinder head bolts and spark plug. * Head gasket and/or spark plug gasket damaged. Replace the head and spark plug gaskets.
  • K
    kristen98Aug 25, 2025
    What to do if Masalta MS60-2 is hard to start but there is spark?
    • M
      Michael McknightAug 26, 2025
      What should I do if my Masalta Construction Equipment is difficult to start, even though fuel is available and a spark is present at the spark plug? Here's what might be happening: * The ON/OFF switch might be shorted. Check the switch wiring and replace the switch if necessary. * The ignition coil could be defective. Replace the ignition coil. * The spark gap might be improper, or the points dirty. Set the correct spark gap and clean the points. * The condenser insulation might be worn or short circuiting. Replace the condenser. * The spark plug wire could be broken or short circuiting. Replace the defective spark plug wiring.
  • J
    James CampbellAug 28, 2025
    What to do if there is no fuel present at the carburetor in Masalta Construction Equipment?
    • M
      Mary CostaAug 28, 2025
      What to do if there is no fuel present at the carburetor of my Masalta Construction Equipment? The following reasons could be the cause: * Fuel not available in the fuel tank. Fill with the correct type of fuel. * Fuel cock does not open properly. Apply lubricant to loosen the fuel cock level; replace if necessary. * Fuel filter clogged. Replace the fuel filter. * Fuel tank cap breather hole clogged. Clean or replace the fuel tank cap. * Air in the fuel line. Bleed the fuel line.
  • O
    ohowardAug 31, 2025
    Why is Masalta Construction Equipment hard to start with normal compression?
    • M
      Mr. Jimmy PetersAug 31, 2025
      Why is my Masalta Construction Equipment difficult to start when fuel is available, there's a spark, and compression is normal? This could be due to: * Using the wrong fuel type. Flush the fuel system and replace it with the correct type of fuel. * Water or dust in the fuel system. Flush the fuel system. * A dirty air cleaner. Clean or replace the air cleaner.
  • L
    lknightSep 3, 2025
    What causes 'weak in power' but mistires in Masalta Construction Equipment?
    • S
      Sandra GonzalezSep 4, 2025
      What causes 'weak in power' with proper compression but misfiring in Masalta Construction Equipment? The issue may be due to: * Water in the fuel system. Flush the fuel system and replace it with the correct type of fuel. * Dirty spark plug. Clean or replace the spark plug. * Defective ignition coil. Replace the ignition coil.
  • D
    Donald HaleSep 6, 2025
    Why does the engine of Masalta MS60-2 overheat?
    • K
      kristenphillipsSep 7, 2025
      Why does the engine of my Masalta Construction Equipment overheat? It could be due to: * Improper spark plug heat value. Replace it with the correct type of spark plug. * Incorrect type of fuel. Replace it with the correct type of fuel. * Dirty cooling fins. Clean the cooling fins.
  • C
    csteeleSep 12, 2025
    Why does the rotational speed of Masalta Construction Equipment fluctuate?
    • A
      Ashley HolmesSep 12, 2025
      Why does the rotational speed of my Masalta Construction Equipment fluctuate? It could be due to: * The governor not being adjusted correctly. Adjust the governor. * A defective governor spring. Replace the governor spring. * Restricted fuel flow. Check the entire fuel system for leaks or clogs. * The recoil mechanism clogged with dust and dirt. Clean the recoil assembly with soap and water.

Summary

Hazards and Risks

Mechanical Hazards

Potential mechanical dangers during operation and maintenance.

Fire and Explosion Hazards

Risks associated with flammable fuel and explosive conditions.

Chemical Hazards

Dangers from exhaust gases in confined spaces.

Noise Hazards

Risks of hearing damage from excessive noise exposure.

Operation

Pre-Operation Inspection

Essential checks before starting work sessions or every four hours of use.

Engine Start and Stop Procedures

Step-by-step guide for starting and stopping diesel and petrol engines.

Compaction Operation and Site Preparation

Site prep, material moisture, steering, and footing guidance for effective compaction.

Care and Preventive Maintenance

Daily and Routine Service Checks

Daily checks for leaks, plate cleaning, oil levels, and periodic inspections.

Vibrator, Air Filter, and V-Belt Maintenance

Procedures for changing vibrator oil, cleaning air filters, and checking V-belts.

V-Belt and Clutch Inspection

Instructions for checking V-belt tension, replacing belts, and inspecting the clutch.

Specifications

Motor, Drive Belt, and Vibrator Details

Technical data for motor types, drive belt, vibrator frequency, and centrifugal force.

Machine Weight and Bearing Information

Details on operation mass, and types of bearings used in the compactor.

Acoustic Noise, Vibration, and Dimensions

Noise levels, hand-arm vibration data, and machine working dimensions.

Transportation

Safe Machine Transportation

Guidelines for safely moving the plate compactor, including lifting and securing.

Troubleshooting

Engine and Operation Troubleshooting

Common issues, possible causes, and solutions for engine and operational problems.

Warranty and Maintenance Records

Warranty Terms and Conditions

Details on warranty coverage, duration, and owner responsibilities.

Preventative Maintenance Log

Space provided for recording routine service and parts replacement history.

EC Declaration of Conformity

Conformity Assessment and Standards

Declaration of compliance with EU directives and sound testing results.

Masalta MS60-2 Specifications

General IconGeneral
BrandMasalta
ModelMS60-2
CategoryConstruction Equipment
LanguageEnglish