GOLDEN RULES FOR ‘TROUBLE FREE’ OPERATION
START UP
1. Turn on the fuel tap and allow the carburettor to ll.
2. Close the choke on the carburettor completely (for cold starts) by moving
the throttle control fully forward (refer mower owner manual).
3. Pull the starter cord until the engine starts, then open the choke and
allow the engine to warm up at low revs for 3-5 minutes.
4. When the engine is heated enough, adjust the throttle handle to the
required speed.
NOTE: High revs at start up will damage the engine as lubrication is less
effective in a cold engine.
This motor will run at moderate to full speed without problems, providing the
factory approved settings have not been altered.
NEVER run engine indoors or in enclosed, poorly ventilated areas.
Engine exhaust contains carbon monoxide, an odorless and deadly
gas.
Keep hands, feet, hair and loose clothing away from any moving
parts on the engine.
WARNING - Temperature of mufer and nearby areas may exceed
65ºC avoid these areas.