27
Table of conguration variables
CV Description D A Range Note:
1 Loco Address (Standard Short) 3 1... 127 If CV 29 bit 5 = 0
2 Starting Voltage 2 1... 255 CV 2 x (1/255 track voltage)
3 Acceleration Time 3 √ 1... 255 CV 3 x 2ms x (1/255 track v.)
4 Braking Time 3 √ 1... 255 CV 4 x 2ms x (1/255 track v.)
5 Top Speed 255 √ 1... 255 CV 5 x (1/255 track voltage)
6 Mid Speed 64 1... 255 CV 6 x (1/255 track voltage)
5+6 Programming in Register Mode:
Register 6 = CV No.
Register 5 = Value
--- --- CV 5 and CV 6 are not effected
7 Software Version --- --- read only
7 Decoder Reset Functions
(3 Ranges Available)
(see also Attachment 10)
55 basic setting
66 reset motor setting
77 reset lights and functions
8 Manufacturer ID 123 --- read only
9 Motor frequency 0 √ 0... 3 0 = 16 kHz
1 = 2 kHz
2 = 250 Hz
3 = 60 Hz
13 Function Outputs in Analog Mode
(On if Value Set)
3 √ 0... 63 A1 = 1 Add the values to the
A2 = 2 desired functions!
A3 = 4
A4 = 8
A5 = 16
A6 = 32
17 Long Loco Address (High Byte)
128
128...
10239
Only active
if CV29 bit 5 = 1
18 Long Loco Adress (Low Byte)
19 Consist adress 0 0... 99 Autom. consist address Lenz
®
29 Conguration Table NMRA 4 √ see Attachment 1
49 Conguration Table MASSOTH 2 √ see Attachment 2
50 Light: Dimming Value (PWM) 32 √ 1... 32 32 = full track voltage