Dear Customer, thank you for purchasing a MASTER product.
Here you will find important information regarding the methods of use and the safety of installation.
WIND P is a wind sensor device for awnings, screens or similars. This device rolls up the awning when wind
speed exceeds the setting threshold. It controls only one motor with mechanical limit switch.
Comply with the following information
and keep for future reference.
FOR A CORRECT INSTALLATION, IT IS RECOMMENDED TO READ THIS INSTRUCTION GUIDE.
The producer cannot be consider responsable for any damages due to improper, wrong or unreasonable use.
WARNINGS
1. Technical and general features (related to 20°C working temperature)
Power Supply :
Contacts capacity :
Dimensions :
Wind threshold :
230 Vac 50/60 Hz
10 A@250 Vac
100 x 100 x 60 mm
from 7 to 40 Km/h
01.
02.
03.
04.
05.
06.
07.
08.
09.
10.
11.
12.
13.
14.
15.
16.
17.
The device must be installed by technical qualified staff so as to comply with the laws in force in your locality.
Check that the package is intact and it has not suffered damage in transit.
This device is subject by dangerous electric voltage.
Always connecting with ground wire (yellow/green).
Manual controls with high voltage, be carefull.
The installer is forced to arrange a section device on the system (with 3 mm minimum opening contacts)
Do not change,open or replace parts without manufacturer’s permission..
For your safety, is forbidden working close to the roller tube with motor supplied.
In case of malfunctioning do not keep on control and warn the technician.
Operating on the device with caution, using suitable tools.
Check that the power supply line does not depend on circuit for lighting.
The device has not section part, the technician will take care to provide it into the system.
Be sure that sensor has been installed on the correct position and well exposed to the wind and that there are no obstacles to the blades rotation.
Strictly adjusting the sensor with blades turned upside.
Using sensors produced by the same manufacturer, or the warranty will be cancelled.
The producer cannot be consider responsable for any damages due to improper, wrong or unreasonable use.
Make connections without power supply.
Adjusting the motor limit switch before connect it to the device.
2. Warnings on installation safety
WIND
Instruction guide : wind control for 1 motor
The device is proveded by one manual control that can be permanent or momentary. Through this control is possible move the awning, manually.The manual control will be disabled in wind alarm
condition.
3. Manual control
Expired
At the end of the product cycle, dispose as provide by local regulation, or deliver again to the retailer when purchasing a new one. This product could contain polluting substance for the
environment and dangerous for health, if expired in a wrong way.
WIND rev.02 dated 30.08.12
Sensor supported :
Protection Degree :
Protective fuse:
sensor X15C
Ip55
5x20 fast 3,15 Amp
Working temperature : from -20°C to +55°C
It closes the awning when the wind speed exceeds the set threshold for longer than 3 seconds.
It exits from wind alarm mode after about 8 minutes . During the wind alarm mode, the manual controls are disabled.
rotating the trimmer on the device. Threshold is adjustable from 7 Km/h (trimmer completed rotate on the left) to a 40 Km/h (trimmer completed rotate on the right).
The factory set up the wind threshold at about 15 Km/h.
when the set wind threshold is exceeded,the red led switch on. If this condition continues for at least 3 seconds, the device enter into wind alarm mode and red led flashes for the whole wind alarm
time.
once device connected and wind alarm simulated (putting the awning in middle position and rotating the sensor blades) it can be possible exit from alarm condition without waiting 8 minutes
expeted. Keep hold key RESET since led (flashing during the alarm) switch off(about5seconds).
How to adjusting wind threshold :
Wind presence signal :
Forced exit from wind alarm mode :
4. Wind control
5. Fixing System
connection cables
X
connection cables
X
X
WRONG FIXING
RIGHT FIXING
R
WIRED
Question and Answer IconNeed help?

Do you have a question about the Master WIND and is the answer not in the manual?

Summary

Technical and General Features

Installation Safety Warnings

Electrical Safety and Installation Precautions

Ensures safe installation by qualified staff, emphasizing electrical safety, proper grounding, and avoiding unauthorized modifications.

Manual Control Operation

Wind Control Functionality

Adjusting Wind Speed Threshold

Explains how to adjust the wind speed threshold using a trimmer, detailing the range and factory settings.

Wind Alarm Indicators and Exit

Describes the red LED indicator for wind speed exceeding threshold and the procedure for exiting wind alarm mode.

Fixing System Guidelines

Correct and Incorrect Fixing Methods

Illustrates the proper and improper methods for physically mounting the device to ensure correct operation.

Device Schematic Overview

Electric Connection Scheme

Wind Sensor and Power Connections

Details the wiring diagram for connecting the wind sensor, power supply, and manual control to the main unit.

Connection Schemes for Grouping Modules

WIND to Grouping Module X52

Provides the specific wiring diagram for connecting the WIND unit to the X52 grouping module.

WIND to Grouping Module X54

Provides the specific wiring diagram for connecting the WIND unit to the X54 grouping module.

System Check Procedure

Verification of Connections and Operation

Outlines the steps to verify correct wiring and test the system's response to wind alarm conditions.

Overview

This document describes the MASTER WIND P, a wind control device designed for awnings, screens, and similar applications. Its primary function is to automatically retract an awning when wind speed exceeds a predefined threshold, thereby protecting the awning from potential damage. The device is specifically designed to control a single motor equipped with mechanical limit switches.

Function Description

The WIND P operates as a safety mechanism for awnings, activating a retraction sequence when wind conditions become too strong. The device continuously monitors wind speed through a connected sensor (model X15C). When the measured wind speed surpasses the user-adjustable threshold for a continuous period of at least 3 seconds, the device enters a "wind alarm" mode. In this mode, the awning is automatically closed. A red LED indicator on the device illuminates when the wind threshold is exceeded and flashes during the entire wind alarm period, providing a visual cue to the user.

Once in wind alarm mode, the device maintains the awning in a closed position for approximately 8 minutes. During this period, any manual controls for the awning are disabled to prevent accidental deployment while wind conditions are still potentially hazardous. After the 8-minute safety period, the device automatically exits wind alarm mode, and manual control is restored.

The wind threshold is adjustable by the user via a trimmer located on the device. This allows the user to customize the sensitivity of the wind control to suit their specific environment and awning type. The adjustment range for the wind threshold is from 7 Km/h (when the trimmer is fully rotated to the left) to 40 Km/h (when the trimmer is fully rotated to the right). The device is factory-set to a default wind threshold of approximately 15 Km/h.

In addition to the automatic wind control, the device also features a manual control option. This allows users to manually operate the awning, moving it to a desired position. This manual control can be configured for either permanent or momentary operation, offering flexibility in how the awning is managed. However, as noted, this manual control is overridden and disabled when the device is in wind alarm mode.

A "RESET" key is integrated into the device, providing a mechanism for users to manually exit the wind alarm mode prematurely, without waiting for the full 8-minute period. This feature is particularly useful during installation or testing. To force an exit from wind alarm mode, the user must press and hold the RESET key until the flashing red LED (indicating alarm mode) switches off, which typically takes about 5 seconds. This functionality is also used during the system check procedure to verify correct wiring and motor operation.

Usage Features

The WIND P is designed for straightforward operation once installed. The primary interaction for the user involves setting the desired wind threshold and, if necessary, utilizing the manual control or the RESET function.

  • Wind Threshold Adjustment: The wind threshold is adjusted using a rotary trimmer on the device. Users can turn the trimmer to the left to decrease the sensitivity (higher wind speed required for retraction) or to the right to increase sensitivity (lower wind speed required for retraction). This allows for fine-tuning based on local weather patterns and the awning's resilience.
  • Visual Indicators: The red LED serves as a clear visual indicator of the device's status. A steady red light indicates that the wind threshold has been exceeded, while a flashing red light signifies that the device is in wind alarm mode and the awning is retracted.
  • Manual Control: The integrated manual control allows for convenient operation of the awning outside of wind alarm conditions. This can be used to extend or retract the awning at will, providing flexibility for shade or light control.
  • System Check: During installation, a system check procedure is recommended to ensure correct wiring. This involves placing the awning in an intermediate position and rotating the sensor blades to simulate a wind alarm. The awning should then move upward. If it moves downward, the motor's wiring needs to be reversed. This check is crucial for safe and correct operation.
  • Forced Exit from Alarm: The RESET key offers a practical way to override the 8-minute wind alarm timer. This is particularly useful during initial setup or if the user needs to quickly restore manual control after a brief gust of wind.

Maintenance Features

The WIND P is designed for minimal maintenance, focusing on reliable operation and safety.

  • Installation by Qualified Staff: The device requires installation by technically qualified staff who are familiar with local electrical regulations. This ensures proper wiring, grounding, and adherence to safety standards, which is the foundation for reliable long-term operation.
  • Sensor Placement: Proper placement of the wind sensor is critical for accurate readings. The sensor must be installed in a position that is well-exposed to the wind, free from obstacles that could impede the rotation of its blades. The blades should also be adjusted strictly in an upside-down position for optimal performance.
  • Fuse Protection: The device incorporates a protective fuse (5x20 fast 3.15 Amp) to safeguard against electrical overloads, enhancing the device's longevity and safety. In case of an electrical issue, the fuse is designed to blow, preventing damage to the device and potentially the motor.
  • No User-Serviceable Parts: Users are explicitly warned against changing, opening, or replacing parts of the device without the manufacturer's permission. This indicates that the device is not designed for user-level repairs or modifications, emphasizing the importance of professional servicing if issues arise.
  • Use of Compatible Sensors: To maintain warranty validity and ensure proper functioning, it is recommended to use sensors produced by the same manufacturer. Using incompatible sensors could lead to malfunctions and void the product warranty.
  • Disposal: At the end of its lifecycle, the product should be disposed of according to local regulations or returned to the retailer when purchasing a new one. This highlights the manufacturer's awareness of environmental responsibility and the potential for the product to contain substances that require specific disposal methods.
  • Warning for Malfunctioning: In case of a malfunction, users are instructed not to continue control and to warn a technician. This emphasizes safety and the need for professional intervention for troubleshooting and repair.

Master WIND Specifications

General IconGeneral
ColorBlack
Connectivity TechnologyBluetooth
PlatformAndroid
BatteryRechargeable Lithium-ion
Motion ControlsYes
VibrationDual Vibration Motors

Related product manuals