5
- Never use faulty or damaged electrical 
equipment (this also applies to extension cords 
and plug connections).
 CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety 
regulations and instructions may result in an 
electric shock, re and/or serious injury.
Keep all safety regulations and instructions in a 
safe place for future use.
3. Proper Use
The device is designed for applications operated 
with a 120 V alternating current source.
Be sure to observe the restrictions in the safety 
instructions. The generator is intended to 
provide electric tools and light sources with 
electricity. When using the device with household 
appliances, please check their suitability in 
accordance with the relevant manufacturer’s 
instructions. In case of doubt, ask an authorized 
dealer of the respective appliance. The machine 
is to be used only for its prescribed purpose. Any 
other use is deemed to be a case of misuse. The 
user/operator and not the manufacturer will 
be liable for any damage or injuries of any kind 
caused as a result of such misuse.
4. Technical data 
AC frequency (Hz):                                                60 Hz
Continuous rated power (S1):                        1200 W
Maximum power max:                          1500W
Ac output voltage:                                                 120V
Rated/max ac current 120V:                      10 AMPS 
DC output:                                  12V
Sockets:                                                                 2*120V
Engine:         SINGLE-CYLINDER FORCED  
                                          AIR-COOLED 4-STROKE OHV
Power:                                                3 HP / 3600 rpm
Displacement(cc):                                                98 CC
Starting system:                           hand recoil start
- Never operate the generator in rain or snow.
- Never touch the generator with wet hands.
- Guard against electric danger. When working 
outdoors, use only extension cords that are 
approved for outdoor use and which are marked 
accordingly (H07RN).
- The overall length of the extension cords used 
may not exceed 50 m for 1.5 mm
2
 and 100 m for 
2.5 mm
2
.
- No changes may be made to the settings of the 
motor or generator. 
- Repairs and adjustment work may only be 
carried out by trained and authorized  personnel.
- Do not refuel or empty the tank near open 
lights, re or sparks. Do not smoke!
- Do not touch any mechanically driven or hot 
parts. Do not remove the safety guards.
- Do not expose the tools to damp or dust. 
Permissible ambient temperature – 10 to + 40°C, 
max. altitude above sea level 1000 m, relative 
humidity: 90 % (non-condensing).
- The generator is driven by a combustion engine, 
which produces heat in the area of the exhaust (on 
the opposite side of the sockets) and the exhaust 
outlet. You should therefore keep clear of these 
surfaces because of risk of skin burns.
- The values quoted in the technical data for 
sound power level (LWA) and sound pressure level 
(LWM) are emission values and not necessarily 
reliable workplace values. As there is a correlation 
between emission and emission levels, the 
values are not a reliable basis for deciding on any 
additional precautions which may be needed. 
Factors inuencing the actual user emission level 
include the properties of the work area, other 
sound sources etc., the number of machines 
and other processes in the vicinity, as well as the 
time span in which the operator is subjected to 
the noise. Also, the permitted emission level can 
vary from country to country. Nevertheless, with 
this information the user is able to make a better 
assessment of the dangers and risks involved.