SERVICE AND SPECIAL FUNCTIONS
Table of Contents
Touch / TouchXL Console
64
Troubleshooting Guide
Top Level
Models
Sub-Level 1
Sub Level 2
Default
Value
Values/Range
Notes
TV
THUREASC
Input Source
OFF
OFF/TV/Wireles
s
TV/CABLESAT
THUREASC
Idle Standby
ECO
ECO / Always
ON
ECO:Turn off TV Power after workout ends
Always ON: Don't turn off TV Power after workout ends
THUREASC
Default Volume
Input
No Value
1 - 15
Has value only if Wireless TV is Input Source, then Default
=
15
Max
No Value
1 - 32
Has value only if Wireless TV is Input Source, then Default
=
32
Output
No Value
1 - 32
Used for all Input Sources except OFF.
Default = 5 if not OFF
Top Level
Models
Sub-Level 1
Sub Level 2
Default
Value
Values/Range
Notes
Calibration
TA
Auto Calibration
Treadmill: Finds the lowest and highest incline positions
and records the ADC range (+/- an offset determined by a
system engineer) of the incline motor.
Ascent: Sends command to the LCB to calibrate the incline for
itself. Finds the lowest and highest incline and records the ADC
values in the LCB. The console will display some of the messages
listed.
T
Elevation Min
Set the min incline ADC value. This is usually set to a value
found by using the Calibration function and an offset
determined by a
system engineer.
T
Elevation Max
Set the max incline ADC value. This is usually set to a value
found by using the Calibration function and an offset
determined by a
system engineer.
A
Elevation Tuner
Original Incline Tuner of A5x
EN ClimbMill
Start Calibration
Prompts user to input weight. Does this using keypad to enter
weight and enter to confirm. When the user presses enter,
console prompts user to press start. This will start calibration
for
40 seconds.